View larger
S811+R13P3S 168983 Y7-168983 EATON ELECTRIC Soft starter, 3p, 135A, Ue 200-600VAC
S811+R13P3S
168983
Y7-168983
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller S811+R13P3S soft starter regulates startup currents and voltage ramps in three-phase industrial motor systems to reduce mechanical shock and electrical stress. These electronic motor controllers provide smooth acceleration profiles for heavy machinery, pumps, and conveyor systems.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 135 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 37 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 75 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
CSA
UL File No.: E202571
CSA22.2-14-1995
CE
UL 508
CSA File No.: LR 353
UL
CCC
GB14048
C-Tick
IEC/EN 60947-4-2
UL Category Control No.: NMFT
CSA Class No.: 3211-06, 2411-01
Features & Functions
Motor overload protection
Internal bypass
Display
Overload monitoring
Single direction
Suppression of DC components for motors
Suppression of closing transients
Underload monitoring
Soft start function
Current limitation
Potential isolation between power and control sections
General
NEMA Other
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
1 x (2.5 - 95) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 95) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
1 x (14 - 12), Control circuit cables
1 x (14 - 4/0), Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
0.6 x 3.5 mm, Terminal screws, Control circuit cables
0.4 Nm, Screw terminals, Control circuit cables
Control circuit
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
1000 mA, Control circuit, Regulator supply
Input/Output
24 V DC
Soft start function
Max. 2000 ms (Kickstart Duration)