View larger
S811+R10P3S 168981 Y7-168981 EATON ELECTRIC Soft starter, 105 A, 200 600 V AC, Us 24 V DC, with control unit..
S811+R10P3S
168981
Y7-168981
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller soft starter model S811+R10P3S is a solid-state electronic control device used to provide gradual motor acceleration and deceleration for three-phase AC machinery.
Industrial plants rely on this category of equipment to limit electrical grid disturbances, protect mechanical linkages from high starting torques, and maintain stable operational profiles across manufacturing lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 105 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 30 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 55 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL 508
GB14048
UL
CSA
CSA-C22.2 No. 14
UL File No.: E202571
CSA Class No.: 3211-06, 2411-01
CSA22.2-14-1995
CCC
IEC/EN 60947-4-2
CE
C-Tick
CSA File No.: LR 353
Features & Functions
Motor overload protection
Display
Internal bypass contacts
Overload monitoring
Potential isolation between power and control sections
Current limitation
Soft start function
Suppression of DC components for motors
Single direction
Min. ramp time 1 s - fast switching (semiconductor contactor)
Underload monitoring
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 95) mm², Main cables
1 x (14 - 12), Control circuit cables
2 x (14 - 12), Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 95) mm², Main cables
0.6 x 3.5 mm, Terminal screws, Control circuit cables
11.3 Nm
Control circuit
150 mA, Control circuit, Digital inputs, External 24 V
1000 mA, Control circuit, Regulator supply
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
Input/Output
24 V DC
Soft start function
Max. 2000 ms (Kickstart Duration)