Signal column; D=40 mm; Base Module; 800 mm; Tube and foot SL4-PIB-800 Base module; 800-mm aluminum tube and foot Base module, Color black, Aluminum color tube, Product range: SL signal towers, Connection technique: Push in terminals, Mounting type: for horizontal mounting, Fitted with: Base with aluminum tube and plastic foot, including cover, Tube length: 800 mm, Number of modules: max. 5 modules, For use with: SL4-L-…, SL4-BL-…, SL4-FL-…, SL4-AP-..., Connection to SmartWire-DT: no, Standards: IEC/EN 60947-5-1, IEC degree of protection: IP66, IEC/EN 60529, Protection type UL: Type 4, 4X, 13

Automation > Connection module for signal tower
Auxiliary Control and Signalling Elements

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series SL4 Base module
Catalog Number
177313
Model Code
SL4-PIB-800
EAN
4015081717668
Product Length/Depth
72 mm
Product Height
869 mm
Product Width
72 mm
Product Weight
0.8 kg
Certifications
IEC/EN 60529
IEC/EN 60947-5-1

Features & Functions

Color
Other
Fitted with:
Cover
Aluminum tube
Plastic foot
Number of modules
Max. 5 (with standard base)
Max. 10 (with base for mounting on both sides)
Max. 5

General

Connection to SmartWire-DT
No
Degree of protection
IP66
NEMA 4
NEMA 4X
NEMA 13
Mounting Method
Floor
Horizontal
Bracket
Mounting position
As required
Product Category
SL signal towers
Rated impulse withstand voltage (Uimp)
4000 V AC
Shock resistance
15 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27
Tube length
800 mm
Type
Base module

Climatic environmental conditions

Ambient operating temperature - min
-30 °C
Ambient operating temperature - max
60 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78

Terminal capacities

Terminal capacity (AWG)
24 - 16
Terminal capacity (flexible with ferrule and plastic collar)
0.25 - 0.75 mm²
Terminal capacity (solid/flexible)
0.2 - 1.5 mm²
Terminal capacity (solid/flexible with ferrule)
0.25 - 1.5 mm²

Electrical rating

Rated insulation voltage (Ui)
250 V
Rated operational voltage
24 V AC/DC ± 10 %
230/240 V AC ± 10 %
110/120 V AC ± 10 %

ETIM for 177313 Low-voltage industrial controls and switchgear (EC001152)
Feature Name Feature Value
Connection type auxiliary circuit (EF006820) Spring clamp connection
Suitable for tube mounting (EF001668) No
Suitable for angle mounting (EF001669) Yes
Suitable for floor mounting (EF025108) Yes
Colour (EF000007) Other
Suitable for AS interface (EF005768) No
Suitable for M12 connector (EF017873) No
Suitable for IO link (EF017874) No

Product Datasheet