View larger
NZM4-XA380-440AC/DC 266452 Y7-266452 EATON ELECTRIC Shunt release, 380-440VAC/DC
NZM4-XA380-440AC/DC
266452
Y7-266452
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for off-load switches, the Eaton Moeller NZM4-XA380-440AC/DC 266452 Y7-266452 EATON ELECTRIC Shunt release, 380-440VAC/DC is an auxiliary component that facilitates remote tripping of electrical circuit apparatus. These devices allow operators to safely open switches from remote control stations during system interlocks or emergency interventions. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 380 V
- Rated control supply voltage AC 60 Hz (EF003979): 380 V
- Rated control supply voltage DC (EF003980): 380 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
UL/CSA
RoHS conform
CSA (File No. 22086)
UL listed
CSA-C22.2 No. 5-09
CSA certified
UL489
CE marking
CSA (Class No. 1437-01)
UL (File No. E140305)
UL (Category Control Number DIHS)
Product specifications
- Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) at shunt release
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) for undervoltage releases, off-delayed
440 V AC
380 V AC
440 V DC