View larger
NZM3-XAHIV-230AC-MNS 274141 Y7-274141 EATON ELECTRIC Shunt release, 230VAC, +1early N/O, for mesh network, s..
NZM3-XAHIV-230AC-MNS
274141
Y7-274141
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Equipped with early auxiliary contacts, the NZM3-XAHIV-230AC-MNS 274141 Y7-274141 EATON ELECTRIC Shunt release functions as a remote tripping device for electrical switches. Shunt releases are commonly deployed in safety circuits to enable automated or manual breaker opening from external control stations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 230 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
RoHS conform
Product specifications
- Shunt release for mesh network circuit-breakers in conjunction with NZM-XZM capacitor unit
- Only for short-time operation with a maximum on-time = 1 s
- Operating range 10 - 110 % Us
- not UL/CSA approved
- Rated control voltage 230 V AC
- Cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
- Cannot be used in conjunction with NZM...-XR... remote operator.
- Intermittent operation guaranteed by series connection of an M22-(C)K10 make contact.
- Early-make time of integrated auxiliary contact upon switching on and off (manual operation): approx. 20 ms.
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
18 - 14 AWG (2x) at shunt release
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt release
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule