View larger
NZM1-XAL208-250AC/DC 259744 Y7-259744 EATON ELECTRIC Shunt release, 208-240VAC/DC
NZM1-XAL208-250AC/DC
259744
Y7-259744
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A shunt release device such as the NZM1-XAL208-250AC/DC 259744 Y7-259744 EATON ELECTRIC Shunt release, 208-240VAC/DC provides remote tripping control for compatible circuit breakers and switches. These modules allow control systems to interrupt main power circuits instantaneously during emergency stop conditions. Pricing, stock levels, and fulfillment lead times are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 208 V
- Rated control supply voltage AC 60 Hz (EF003979): 208 V
- Rated control supply voltage DC (EF003980): 208 V
- Voltage type for actuating (EF008242): AC/DC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
UL/CSA
RoHS conform
UL (Category Control Number DIHS)
UL (File No. E140305)
CSA (Class No. 1437-01)
CSA (File No. 22086)
IEC60947
UL listed
CSA-C22.2 No. 5-09
CE marking
CSA certified
Product specifications
- Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (1x) at shunt release
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
250 V AC
250 V DC
208 V AC