View larger
NZM1-XA208-250AC/DC 259726 Y7-259726 EATON ELECTRIC Shunt release, 208-240VAC/DC
NZM1-XA208-250AC/DC
259726
Y7-259726
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as an electrical tripping auxiliary, the Eaton Moeller NZM1-XA208-250AC/DC shunt release enables remote tripping functionality for compatible off-load switches and protective enclosures. These auxiliary release modules receive voltage impulses to instantly unlatch and open switch contacts during safety shutdowns. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 208 V
- Rated control supply voltage AC 60 Hz (EF003979): 208 V
- Rated control supply voltage DC (EF003980): 208 V
- Voltage type for actuating (EF008242): AC/DC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
UL/CSA
RoHS conform
CSA (File No. 22086)
UL (Category Control Number DIHS)
UL listed
CSA (Class No. 1437-01)
UL489
UL (File No. E140305)
IEC60947
CSA certified
CSA-C22.2 No. 5-09
Product specifications
- Switches are tripped by a voltage pulse or by the application of uninterrupted voltage.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt release
250 V DC
250 V AC
208 V AC