EATON - MOELLER +IZM-STS48DC +IZM-STS48DC 122741 EATON ELECTRIC Shunt release, (2), 48VDC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

+IZM-STS48DC 122741 EATON ELECTRIC Shunt release, (2), 48VDC

+IZM-STS48DC

122741

EATON - MOELLER

1 Pcs.

Shunt release, (2), 48VDC Shunt release, Voltage release, For use with: IZM20, 32, 40, 63…, IN20, 32,40, 63…, If ordered separately a secondary terminal unit IZM‐SEC‐… is necessary for connection. Order separately if required. Terminal assignment page 71

Automation > Shunt release (for power circuit breaker)
Circuit Breakers IZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A shunt release is an internal accessory installed within commercial circuit breakers to enable remote tripping and emergency shutdown capabilities from a control station. This Eaton Moeller component provides reliable electrical actuation to quickly sever power during safety interlock events.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Suitable for power circuit breaker (EF005863): No
  • Suitable for off-load switch (EF001543): No
  • Suitable for motor safety switch (EF005826): No
  • Suitable for overload relay (EF001545): No

More info

Shunt release, (2), 48VDC
Shunt release, Voltage release, For use with: IZM20, 32, 40, 63…, IN20, 32,40, 63…, If ordered separately a secondary terminal unit IZM‐SEC‐… is necessary for connection. Order separately if required. Terminal assignment page 71
[

Delivery program

Accessories
Voltage release
Accessories
2nd shunt release for 100 % duty factor
For use with
IZM20, 32, 40, 63…
IN20, 32,40, 63…
Instructions
If ordered separately a secondary terminal unit IZM‐SEC‐… is necessary for connection. Order separately if required. Terminal assignment page 71
,

Technical data

Rated control voltage [Us]
DC [Us]
48 V
Power consumption
DC
(pick-up 250) W
Circuit-breaker response time at Us
35 ms
Operating range
Pick-up voltage [Pick-up]
According to the IEC standard x Uc
,

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C
]

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.