View larger
NZM1-XAHIVL12AC/DC 259790 Y7-259790 EATON ELECTRIC Shunt release, 12VAC/DC, +1early N/O
NZM1-XAHIVL12AC/DC
259790
Y7-259790
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Shunt release type NZM1-XAHIVL12AC/DC 259790 Y7-259790 EATON ELECTRIC Shunt release, 12VAC/DC, +1early N/O is an auxiliary device utilized in industrial switchgear to enable remote tripping functions and interlocking status signaling for circuit protection devices.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 12 V
- Rated control supply voltage AC 60 Hz (EF003979): 12 V
- Rated control supply voltage DC (EF003980): 12 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
UL/CSA
RoHS conform
UL listed
CSA-C22.2 No. 5-09
CSA certified
UL (Category Control Number DIHS)
CE marking
CSA (Class No. 1437-01)
UL489
IEC60947
CSA (File No. 22086)
Product specifications
- Cannot be used in conjunction with NZM...-XR... remote operator.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Early make of auxiliary contact on switching on and off (manual operation): approx. 20 ms.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) at shunt release
18 - 14 AWG (2x) at shunt release
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (2x) for undervoltage releases, off-delayed
12 V DC