View larger
NZM1-XAHIV12AC/DC 259772 Y7-259772 EATON ELECTRIC Shunt release, 12VAC/DC, +1early N/O
NZM1-XAHIV12AC/DC
259772
Y7-259772
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A shunt release with an early auxiliary contact combines remote tripping functions with breaker status feedback for compact industrial distribution assemblies. This Eaton Moeller NZM1-XAHIV12AC/DC device supports reliable safety interlocks within electrical enclosures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 12 V
- Rated control supply voltage AC 60 Hz (EF003979): 12 V
- Rated control supply voltage DC (EF003980): 12 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
UL/CSA
RoHS conform
UL489
CSA (File No. 22086)
UL (File No. E140305)
CSA-C22.2 No. 5-09
UL listed
CSA certified
CSA (Class No. 1437-01)
UL (Category Control Number DIHS)
CE marking
Product specifications
- Cannot be used in conjunction with NZM...-XR... remote operator.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Early make of auxiliary contact on switching on and off (manual operation): approx. 20 ms.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
With 3 m connection cable instead of screw termination
18 - 14 AWG (2x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt release
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
12 V DC