View larger
NZM1-XAHIVL110-130AC/DC 259798 Y7-259798 EATON ELECTRIC Shunt release, 110-130VAC/DC, +1early N/O
NZM1-XAHIVL110-130AC/DC
259798
Y7-259798
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller NZM1-XAHIVL110-130AC/DC is an integrated shunt release featuring auxiliary contact capabilities, designed to add remote tripping and signaling functions to industrial circuit breakers. Such auxiliary assemblies facilitate coordinated control schemes by providing feedback on switch status while enabling remote electrical disconnection. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 110 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): Yes
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): No
- Suitable for overload relay (EF001545): No
More info
▲General specifications
IEC
RoHS conform
CSA certified
CSA (Class No. 1437-01)
UL (File No. E140305)
CSA-C22.2 No. 5-09
UL489
IEC60947
UL (Category Control Number DIHS)
CSA (File No. 22086)
CE marking
Product specifications
- Cannot be used in conjunction with NZM...-XR... remote operator.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Early make of auxiliary contact on switching on and off (manual operation): approx. 20 ms.
- Shunt releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XU... undervoltage release.
Power circuit breaker
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
18 - 14 AWG (1x) at shunt release
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
110 V DC
130 V AC
110 V AC