EATON - MOELLER M22-H4 M22-H4 216551 Y7-216551 EATON ELECTRIC Shroud, for flush mounting plate, 4 mounting locations View larger
Images are for illustrative purposes only. Please refer to data sheet for details

M22-H4 216551 Y7-216551 EATON ELECTRIC Shroud, for flush mounting plate, 4 mounting locations

M22-H4

216551

Y7-216551

EATON - MOELLER

1 Pcs.

Shroud, for flush mounting plate, 4 mounting locations M22-H4 Eaton Moeller® series M22 Shroud, for flush mounting plate, 4 mounting locations Shroud, insulated material, color light gray RAL 7035, for RMQ system, mounting diameter 22.3mm degree of protection IP55 in combination with flush mounting plate M22-E.., 4 knockout cable entries M20, mounting location 4

Automation > Protective cover for command devices
Auxiliary Control and Signalling Elements

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series M22 Accessory Shroud
Catalog Number
216551
Model Code
M22-H4
EAN
4015082165512
Product Length/Depth
110 mm
Product Height
80 mm
Product Width
105 mm
Product Weight
0.181 kg
Compliances
Bureau Veritas
CE Marked
GoST-R
Certifications
CSA Certified
CCC Marked
Lloyd's Register Certified
CE
CSA Class No.: 3211-03
UL 508
CSA-C22.2 No. 14-05
IEC/EN 60947-5
CSA File No.: 012528
CSA-C22.2 No. 94-91
UL
CSA
UL File No.: E29184
UL Category Control No.: NKCR

Features & Functions

Color
Gray
Knockouts
4 x M20 (cable entry knockouts at the base)
Material
Insulated material light
Number of locations
4
RAL-number
7035

General

Degree of protection
NEMA 12
IP40
Protection
Protection type only in combination with flush mounting plates M22-E…
Size
22.5 mm
Type
Four-element

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C

Communication

Connection to SmartWire-DT
No

Contacts

Force for positive opening - min
0 N

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 216551 Low-voltage industrial controls and switchgear (EC000202)
Feature Name Feature Value
Number of appliances to build in (EF000219) 4
Lockable (EF000113) No
Degree of protection (IP) (EF005474) IP40
Degree of protection (NEMA) (EF011959) 12

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.