EATON - MOELLER SDAINLM260(110V50HZ,120V60HZ) SDAINLM260(110V50HZ,120V60HZ) 101028 Y7-101028 EATON ELECTRIC Star-delta contactor combination, 132kW/400V/A.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SDAINLM260(110V50HZ,120V60HZ) 101028 Y7-101028 EATON ELECTRIC Star-delta contactor combination, 132kW/400V/A..

SDAINLM260(110V50HZ,120V60HZ)

101028

Y7-101028

EATON - MOELLER

1 Pcs.

Star-delta contactor combination, 132kW/400V/AC3 SDAINLM260(110V50HZ,120V60HZ) Eaton Moeller® series SDAINL Star-delta contactor combination, 380 V 400 V: 132 kW, 110 V 50 Hz, 120 V 60 Hz, AC operation Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 260 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 75 kW, 380 V 400 V: P= 132 kW, 500 V: P= 160 kW, 660 V 690 V: P= 160 kW, Max. changeover time: 20 s, Actuating voltage: 110 V 50 Hz, 120 V 60 Hz, Voltage AC/DC: AC operation , Individual components of the combination Mains contactor Q11: DILM150, + DILM150-XHI11, Delta contactor Q15: DILM150, + DILM150-XHI31 Part no., Star contactor Q13: DILM95, + DILM150-XHI11 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.

Automation > Combination of contactors
Contactors up to 170A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller star-delta contactor combination manages the multi-stage starting sequence of high-power three-phase motors to minimize peak electrical loads. Heavy industrial facilities utilize these assemblies for large compressors, heavy crushers, and industrial pumps. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Function (EF000030): Star-delta contactor
  • Suitable for rail mounting (EF003972): No
  • Rated control supply voltage AC 50 Hz (EF003978): 110 V
  • Rated control supply voltage AC 60 Hz (EF003979): 120 V
  • Rated control supply voltage DC (EF003980): 0 V
  • Voltage type for actuating (EF008242): AC
  • Number of normally open contacts as main contact (EF001374): 9
  • Type of electrical connection of main circuit (EF006819): Screw connection
  • Voltage type (operating voltage) (EF005294): AC
  • Operating voltage AC 50 Hz (EF008206): 230 V
  • Operating voltage AC 60 Hz (EF008207): 230 V
  • Operating voltage DC (EF008208): 0 V
  • Rated operation current Ie at AC-1, 400 V (EF001393): 260 A
  • Rated operation current Ie at AC-3, 400 V (EF001392): 260 A
  • Rated operation power at AC-3, 400 V (EF001364): 132 kW
  • Rated operation power NEMA (EF011960): 0 kW

More info

▲

General specifications

Product Name
Eaton Moeller® series SDAINL contactor combination
Catalog Number
101028
Model Code
SDAINLM260(110V50HZ,120V60HZ)
EAN
4015081009251
Product Length/Depth
183 mm
Product Height
314 mm
Product Width
308 mm
Product Weight
11.538 kg
Certifications
CE

Features & Functions

Functions
Star-delta contactor
Number Of Poles
Three-pole

General

Application
Star-delta motor starting for contactor combinations
Overvoltage category
III
Pollution degree
3
Product category
Contactor combinations
Suitable for
Also motors with efficiency class IE3
Used with
ETR4-51
Utilization category
AC-3: Normal AC induction motors: starting, switch off during running
Voltage type
AC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C

Electro Magnetic Compatibility

Interference immunity
According to EN 60947-1

Electrical Rating

Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
260 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
260 A
Rated insulation voltage (Ui)
690 V
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
260 A
Rated operational power at AC-3, 380/400 V, 50 Hz
132 kW

Switching time

Changeover time
20 s, max.

Magnet system

Duty factor
100 %
Rated control supply voltage (Us) at AC, 50 Hz - min
110 V
Rated control supply voltage (Us) at AC, 50 Hz - max
110 V
Rated control supply voltage (Us) at AC, 60 Hz - min
120 V
Rated control supply voltage (Us) at AC, 60 Hz - max
120 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V

Communication

Connection
Screw terminals

Contacts

Number of auxiliary contacts (normally closed contacts)
1
Number of auxiliary contacts (normally open contacts)
1

Design verification

Equipment heat dissipation, current-dependent Pvid
78.8 W
Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
260 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.