View larger
ESR5-NZ-21-24VAC-DC 118703 Y7-118703 EATON ELECTRIC Safety two-hand relay, 24VDC/AC, 2-channel, 2 enabling p..
ESR5-NZ-21-24VAC-DC
118703
Y7-118703
EATON - MOELLER
1 Pcs.
Automation > Two-hand control relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller ESR5-NZ-21-24VAC-DC safety two-hand relay evaluates dual-channel input signals from operator control stations to ensure safe machinery activation only when both hands are correctly positioned. Such components prevent accidental machine startup and protect personnel.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection: Screw connection
- Suitable for rail mounting: true
- With detachable clamps: true
- Voltage type (supply voltage): AC/DC
- Supply voltage AC 50 Hz: 24 V
- Supply voltage AC 60 Hz: 24 V
- Supply voltage DC: 24 V
- Type of switch function of the inputs: Normally closed contact and normally open contact
- With feedback circuit: true
- With start input: false
- Type of control voltage 1: AC/DC
- Control voltage 1: 24 V
- Type of control voltage 2: AC/DC
- Control voltage 2: 24 V
- Voltage type (operating voltage): AC/DC
- Operating voltage AC 50 Hz: 24 V
More info
▲General specifications
UL
CSA-C22.2 No. 14-95
EN 50178
CE
UL Category Control No.: NKCR; NKCR7
UL 508
UL report applies to both US and Canada
UL File No.: E29184
IEC 61508, Parts 1-7
2014/30/EU
IEC/EN 60204
CSA Class No.: 3211-83; 3211-03
EN 574 Part no. IIIC
Certified by UL for use in Canada
EN ISO 13849-1
Machines 2006/42/EG
Feature & Functions
Automatic start
2 Non-delayed enable current paths
Basic insulation
Monitoring of external contactor/expansion unit
Safe insulation
Detachable clamps
Feedback circuit
Approval for TÜV
Two-hand function
Enclosure: Polyamide (PA), not reinforced
General information
125 mA, AC
Terminals: IP20
Installation location: ≥ IP54
Enclosure: IP20
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
EN 574 Type III C
SIL 3, Safety integrity level, In accordance with IEC 61508
Cat. 4, Category
12.1 x 10-10, PFHd, Probability of failure per hour
SIL 3, Safety integrity level
Module used to safely interrupt electrical circuits
Safety relay for monitoring two-hand control per EN 574 Type IIIC and protective door switches
Ambient conditions, mechanical
In accordance with IEC 60947-5-1, Outputs
0.4 W
5 A at 3600 O/h, DC-13 at 24 V, Outputs
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-3
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95
Terminal capacities
2 x (0.2 – 1) mm², solid
2 x (0.25 – 1) mm², flexible with ferrule
24 - 12 AWG, solid or stranded
1 x (0.25 – 2.5) mm², flexible with ferrule
2, Terminal screw, Pozidriv screwdriver
Electrical rating
1.5 W (DC operated)
230 V AC
Approx. 24 V DC at input, starting and feedback circuit
Fuse 6 A gL/gG, For output circuits, External
10A gL/gG, NEOZED (N/O), Output fuse, External, Output data
Input/Output
42 W max., inductive load (τ = 40 ms), at 110 V DC
42 W max., inductive load (τ = 40 ms), at 220 V DC
144 W max., resistive load (τ = 0 ms), at 24 V DC
288 W max., resistive load (τ = 0 ms), at 48 V DC
42 W max., inductive load (τ = 40 ms), at 24 V DC
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
42 W max., inductive load (τ = 40 ms), at 48 V DC
88 W max., resistive load (τ = 0 ms), at 220 V DC
50 ms typ. (K1, K2 - for UN automatic mode)
50 ms typ. (K1, K2 - for UN manual operation)
50 ms typ. (at Uₑ in manual mode)
6 A N/C, Limiting continuous current