View larger
ESR5-NOS-31-230VAC 153152 Y7-153152 EATON ELECTRIC Safety relay emergency stop/protective door, 230VAC, 3 en..
ESR5-NOS-31-230VAC
153152
Y7-153152
EATON - MOELLER
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller ESR5-NOS-31-230VAC is an emergency stop safety relay configured to continuously monitor protective door circuits and emergency stop buttons. Safety relays provide dependable fault reaction and signal interruption to maintain a safe working environment in automated industrial plants.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 230 V
- Supply voltage AC 60 Hz (EF007533): 230 V
- Supply voltage DC (EF007534): 0 V
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- Evaluation inputs (EF008245): 1-channel
- Power consumption (EF000346): 5.43 W
- With start input (EF003342): Yes
More info
▲General specifications
2014/30/EU
CSA-C22.2 No. 14-95
UL 508
EN 50156-1
UL report applies to both US and Canada
UL Category Control No.: NKCR; NKCR7
CE
Certified by UL for use in Canada
CSA Class No.: 3211-83; 3211-03
EN 50178
IEC/EN 60204
UL
EN ISO 13849-1
IEC 61508, Parts 1-7
IEC 62061
Machines 2006/42/EG
Feature & Functions
Reinforced insulation
3 Non-delayed enable current paths
Safe insulation
Basic insulation
Automatically/manually monitored start
Approval for TÜV
Start input
Approval according to UL
Detachable clamps
Enclosure: Polyamide (PA), not reinforced
General information
Enclosure: IP20
IP20
Installation location: ≥ IP54
Rail mounting possible
SILCL 1, Safety integrity level claim limit
SIL 1, Safety integrity level, In accordance with IEC 61508
2.42 x 10-10, PFHd, Probability of failure per hour
Module used to safely interrupt electrical circuits
Safety relay for monitoring emergency stop and protective door switch
Monitoring of position switches
Ambient conditions, mechanical
In accordance with IEC 60947-5-1, Outputs
Climatic environmental conditions
Cold to EN 60068-2-1
Damp heat, constant, to IEC 60068-2-3
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95
Terminal capacities
2 x (0.2 – 1) mm², solid
2 x (0.25 – 1) mm², flexible with ferrule
1 x (0.2 – 2.5) mm², solid
1 x (0.25 – 2.5) mm², flexible with ferrule
0.6 x 3.5 mm, Terminal screws
Electrical rating
230 V AC
Approx. 24 V DC at input, starting and feedback circuit
Fuse 6 A gL/gG (Signal current paths), For output circuits, External
6A gL/gG, NEOZED (N/C), Output fuse, External, Output data
Input/Output
40 W max., inductive load (τ = 40 ms), at 48 V DC
2000 VA, max., resistive load (τ = 0 ms), at 250 V AC
48 W max., inductive load (τ = 40 ms), at 24 V DC
35 W max., inductive load (τ = 40 ms), at 110 V DC
144 W max., resistive load (τ = 0 ms), at 24 V DC
33 W max., inductive load (τ = 40 ms), at 220 V DC
230 W max., resistive load (τ = 0 ms), at 48 V DC
68 W max., resistive load (τ = 0 ms), at 110 V DC
300 ms typ. (at Uₑ in automatic mode)
330 ms typ. (if actuated via A1 or S11/S12)
300 ms typ. (K1, K2 - for UN automatic mode)
50 ms typ. (at Uₑ in manual mode)
Normally 150 ms (on actuation via A1)
6 A N/O, Limiting continuous current