An Eaton Moeller safety relay provides dependable logic processing and error monitoring for safety-critical machine functions and emergency stop circuits. Safety relays protect operators and equipment by continuously supervising protective devices and shutting down hazardous processes reliably upon fault detection. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 20.4 V
- Voltage type (supply voltage) (EF002991): DC
- Switching current (EF000188): 8 A
- Power consumption (EF000346): 6 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 4
- Number of digital inputs (EF001992): 14
- Number of digital outputs (EF001993): 5
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 1
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
EN 50156-1
CSA-22.2 No. 142-MI1987
CE
EN 50581
UL 508
IEC 62061
IEC 61508
EN 50178
IEC/EN 61000-6-2
CSA-C22.20.4-04
CSA
UL File No.: CSA report applies to both US and Canada
IEC/EN 61000-4-2
EN ISO 13849-1
UL Category Control No.: NRAQ
CSA File No.: 012528
EN 50156-2
IEC/EN 61000-6-3
Features & Functions
Safety/standard circuit diagram
Display
Expandable standard inputs/outputs
Keypad
Relay output
Expandable standard bus systems
Real time clock
Redundancy
General
± 2 s/day (± 0.5 h⁄year), Real-time clock, normally
50 m, unscreened, Transistor outputs
1000 m, shielded, Single cable length of test signal output to the device input, Digital inputs 24 V DC
3000 m, shielded, Total of single cable lengths from one test signal output to the device inputs, Digital inputs 24 V DC
T0.95 ≈ 3 x T0.65 = 3 x L/R (Inductive load to EN 60947-5-1, Without external suppressor circuit)
T0.95 = Time in ms, until 95 % of the steady-state current has been reached (Inductive load to EN 60947-5-1, Without external suppressor circuit)
10,000,000 Operations
Wall mounting/direct mounting
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
900 Operations/h at input (does not apply to I1, I2, if function block SM or OM is used)
Resistive load < 100 kΩ, depending on program and load
≤ 5 %
DC-13, 24 V DC, 0.1 Hz: 40000 operations (in accordance with IEC 60947-5-1), Relay outputs
AC-15, 230 V AC, 3 A: 80000 operations (in accordance with IEC 60947-5-1), Relay outputs
DC: B300 (in accordance with UL 508), Relay outputs
0.5 Hz, Transistor outputs, Inductive load to EN 60947-5-1, with external suppressor circuit, Max. switching frequency, max. duty factor = 50%
Ambient conditions, mechanical
Climatic environmental conditions
Condensation: prevent with appropriate measures
Electro magnetic compatibility
4 kV, Signal cable
According to IEC/EN 61000-4-4
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
30 V/m (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Class B (EN 55011)
2 kV, Supply cables, symmetrical, power pulses (Surge), EMC
4 kV, semi-conductor outputs, symmetrical, power pulses (Surge), EMC
According to EN 61131-2
Terminal capacities
0.2 - 4 mm² (AWG 22 - 12), solid
Electrical rating
5.7 mA (Digital inputs, at 24 V DC, at signal 1, I1 - I6)
Output Voltage@≤ 2.4 V (at signal 0 at external load < 10 MΩ, transistor outputs)
U = Uₑ - 1 V (signal 1 at Iₑ = 0.5 A, transistor outputs)
24 V DC (digital inputs)
> 15 V DC on 1 signal
250 V AC
20.4 - 28.8 V DC
24 V DC (transistor outputs)
20.4 - 28.8 V DC (Transistor outputs)
< 5 V DC on 0 signal
≤ 8 A, Back-up fuse, Transistor outputs
60/100 mA, Normally⁄max., On 1 signal, Transistor outputs
Communication
1000 kBit/s, 6 m, easyNet
20 kBit/s, 700 m, easyNet
250 kBit/s, 40 m, easyNet
125 kBit/s, 125 m, easyNet
50 kBit/s, 300 m, easyNet
10 kBit/s, 1000 m, easyNet
Input/Output
4 Transistor Outputs
4 Test signal outputs (T1 - T4)
1 ms (Off test pulse)
Safety
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between easyNet and Power supply: yes
Between Digital inputs 24 V DC and easyNet: yes
Between easyNet and PC interface: yes
Between Relay outputs and Interface: yes
Between easyNet and Memory card: yes
Between Power supply and easyNet: yes
Between Relay outputs and Inputs: yes
Between easyNet and Inputs: yes
Between Relay outputs and Power supply: yes
Between Digital inputs 24 V DC and Outputs: yes
Basic isolation: 600 V AC (Relay outputs)
Between Relay outputs and Digital inputs: yes
Between Relay outputs and easyNet: yes
Between Inputs and internal Power supply: Yes
Between Transistor output and interface: yes
Between Transistor outputs and easyLink: yes
Between Power supply and Inputs: yes
Between Power supply and Outputs: yes
- !
- Protection of an Output relay - Fuse: 6 A gL/gG, Circuit-breaker with C characteristic: 4 A (only permissible with 24V DC), Short-circuit current IK: < 250 A
300 V AC, Between coil and contacts, According to EN 50178
According to EN 50156
OSSD input
Highest speed monitoring
Stopping in the event of an emergency
Zero speed monitoring
3 redundant relay outputs, 6 months test interval
Two-hand control
Safety timing relay
Enabling switch
ESPE with muting function
Protective door
Mode selection
Cat. 4, Category
SIL 3, Safety integrity level, In accordance with IEC 61508
23 x 10-10, PFHd, Probability of failure per hour