View larger
ES4P-221-DMXX1 111016 Y7-111016 EATON ELECTRIC Safety relay, 24 V DC, 14DI, 4DO-Trans, 1DO relay, display, e..
ES4P-221-DMXX1
111016
Y7-111016
EATON - MOELLER
1 Pcs.
Automation > Logic module
EASY programmable relays and MFD displays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller ES4P-221-DMXX1 safety relay is utilized within industrial machine safety loops to monitor critical inputs such as emergency stops and safety gates, safely interrupting control power when a hazard is detected. These devices are standard in automated manufacturing plants to protect operators and machinery by ensuring reliable, fault-tolerant stop functions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 20.4 V
- Voltage type (supply voltage) (EF002991): DC
- Switching current (EF000188): 8 A
- Power consumption (EF000346): 4 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 4
- Number of digital inputs (EF001992): 14
- Number of digital outputs (EF001993): 5
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 1
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
EN Listed
CSA Certified
CE
EN ISO 13849-1
EN 50156-1
EN 50581
IEC/EN 61000-4-2
CSA
CSA-C22.20.4-04
IEC 61508
UL Category Control No.: NRAQ
UL File No.: CSA report applies to both US and Canada
CSA File No.: 012528
IEC/EN 61000-6-2
UL 508
CSA-22.2 No. 142-MI1987
EN 50156-2
EN 50178
IEC/EN 61000-6-3
CSA Class No.: 2252-81; 2252-01
IEC 62061
Features & Functions
Safety/standard circuit diagram
Real time clock
Relay output
Expandable standard inputs/outputs
Expandable standard bus systems
Thermal cutout
General
± 2 s/day (± 0.5 h⁄year), Real-time clock, normally
3000 m, shielded, Total of single cable lengths from one test signal output to the device inputs, Digital inputs 24 V DC
50 m, unscreened, Transistor outputs
100 m, unscreened, Digital inputs 24 V DC
T0.95 = Time in ms, until 95 % of the steady-state current has been reached (Inductive load to EN 60947-5-1, Without external suppressor circuit)
100 % (Inductive load to EN 60947-5-1, With external suppressor circuit)
10,000,000 Operations (Relay outputs)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Wall mounting/direct mounting
900 Operations/h at input (does not apply to I1, I2, if function block SM or OM is used)
13500 Operations/h at resistive load
≤ 5 %
AC-15, 230 V AC, 3 A: 80000 operations (in accordance with IEC 60947-5-1), Relay outputs
DC: B300 (in accordance with UL 508), Relay outputs
DC-13, 24 V DC, 0.1 Hz: 40000 operations (in accordance with IEC 60947-5-1), Relay outputs
0.5 Hz, Transistor outputs, Inductive load to EN 60947-5-1, with external suppressor circuit, Max. switching frequency, max. duty factor = 50%
Ambient conditions, mechanical
Climatic environmental conditions
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 142, EN 60664-1:2003
Electro magnetic compatibility
According to IEC/EN 61000-4-4
4 kV, Signal cable
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Class B (EN 55011)
4 kV, semi-conductor outputs, symmetrical, power pulses (Surge), EMC
2 kV, Supply cables, symmetrical, power pulses (Surge), EMC
According to EN 61131-2
Terminal capacities
0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule
Electrical rating
5.7 mA (Digital inputs, at 24 V DC, at signal 1, I1 - I6)
U = Uₑ - 1 V (signal 1 at Iₑ = 0.5 A, transistor outputs)
Output Voltage@≤ 2.4 V (at signal 0 at external load < 10 MΩ, transistor outputs)
20.4 - 28.8 V DC
24 V DC (transistor outputs)
20.4 - 28.8 V DC (Transistor outputs)
24 V DC (digital inputs)
24 V DC (-15 %/+ 20 % - power supply)
< 5 V DC on 0 signal
> 15 V DC on 1 signal
≤ 8 A, Back-up fuse, Transistor outputs
50/50 mA, Normally⁄max., On 0 signal, Transistor outputs
Communication
1000 kBit/s, 6 m, easyNet
10 kBit/s, 1000 m, easyNet
500 kBit/s, 25 m, easyNet
50 kBit/s, 300 m, easyNet
250 kBit/s, 40 m, easyNet
125 kBit/s, 125 m, easyNet
Input/Output
4 Transistor Outputs
Relay outputs in groups of 1
1 ms (Off test pulse)
Safety
Between Digital inputs 24 V DC and easyNet: yes
Between Transistor outputs and easyLink: yes
Between Relay outputs and easyNet: yes
Between Relay outputs and Power supply: yes
Between Transistor output and interface: yes
Between Digital inputs 24 V DC and Outputs: yes
Between easyNet and Outputs: yes
Between Power supply and easyNet: yes
Between Relay outputs and Digital inputs: yes
Between Inputs and internal Power supply: Yes
Between Power supply and Inputs: yes
Between Relay outputs and Inputs: yes
Between easyNet and Inputs: yes
Between easyNet and PC interface: yes
Basic isolation: 600 V AC (Relay outputs)
Between Relay outputs and Interface: yes
Between easyNet and Memory card: yes
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between Power supply and Outputs: yes
- !
- Protection of an Output relay - Fuse: 6 A gL/gG, Circuit-breaker with C characteristic: 4 A (only permissible with 24V DC), Short-circuit current IK: < 250 A
300 V AC, Between coil and contacts, According to EN 50178
Two-hand control
Protective door
OSSD input
3 redundant relay outputs, 6 months test interval
Stopping in the event of an emergency
Zero speed monitoring
Highest speed monitoring
Safety timing relay
Mode selection
Feedback circuit
According to EN 50156
ESPE with muting function
PL e, Performance level
23 x 10-10, PFHd, Probability of failure per hour
SIL 3, Safety integrity level, In accordance with IEC 61508