View larger
ES4P-221-DRXX1 111018 Y7-111018 EATON ELECTRIC Safety relay, 24 V DC, 14DI, 4DO relays, easyNet
ES4P-221-DRXX1
111018
Y7-111018
EATON - MOELLER
1 Pcs.
Automation > Logic module
EASY programmable relays and MFD displays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller ES4P-221-DRXX1 safety relay functions as a critical protective logic unit designed to monitor emergency stops, safety gates, and light curtains in hazardous industrial machinery zones. Safety relays reliably interrupt power circuits when a safety hazard or fault is detected, safeguarding personnel and equipment.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 20.4 V
- Voltage type (supply voltage) (EF002991): DC
- Switching current (EF000188): 8 A
- Power consumption (EF000346): 6 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 4
- Number of digital inputs (EF001992): 14
- Number of digital outputs (EF001993): 4
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 1
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
IEC/EN 61000-4-2
CSA-C22.20.4-04
EN 50581
IEC 61508
CSA File No.: 012528
EN 50156-1
EN 50156-2
IEC/EN 61000-6-2
EN ISO 13849-1
CE
CSA
CSA Class No.: 2252-81; 2252-01
EN 50178
IEC/EN 61000-6-3
UL Category Control No.: NRAQ
IEC 62061
UL 508
UL File No.: CSA report applies to both US and Canada
Features & Functions
Expandable
Real time clock
Expandable standard bus systems
Relay output
Expandable standard inputs/outputs
General
± 2 s/day (± 0.5 h⁄year), Real-time clock, normally
100 m, unscreened, Digital inputs 24 V DC
3000 m, shielded, Total of single cable lengths from one test signal output to the device inputs, Digital inputs 24 V DC
10,000,000 Operations (Relay outputs)
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Wall mounting/direct mounting
Rail mounting possible
0 %
DC-13, 24 V DC, 0.1 Hz: 40000 operations (in accordance with IEC 60947-5-1), Relay outputs
AC-15, 230 V AC, 3 A: 80000 operations (in accordance with IEC 60947-5-1), Relay outputs
DC: B300 (in accordance with UL 508), Relay outputs
Ambient conditions, mechanical
Climatic environmental conditions
Condensation: prevent with appropriate measures
Electro magnetic compatibility
4 kV, Signal cable
4 kV, Supply cable
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
30 V/m (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Class B (EN 55022)
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
2 kV, Supply cables, symmetrical, power pulses (Surge), EMC
≤ 10 ms
Terminal capacities
0.2 - 4 mm² (AWG 22 - 12), solid
Electrical rating
5.7 mA (Digital inputs, at 24 V DC, at signal 1, I1 - I6)
< 5 V DC on 0 signal
24 V DC (-15 %/+ 20 % - power supply)
20.4 - 28.8 V DC
> 15 V DC on 1 signal
24 V DC (digital inputs)
Communication
10 kBit/s, 1000 m, easyNet
1000 kBit/s, 6 m, easyNet
20 kBit/s, 700 m, easyNet
50 kBit/s, 300 m, easyNet
250 kBit/s, 40 m, easyNet
125 kBit/s, 125 m, easyNet
Input/Output
Relay outputs in groups of 1
1 ms (Off test pulse)
Safety
Between easyNet and Outputs: yes
Between Power supply and Inputs: yes
Between Relay outputs and Inputs: yes
Between Relay outputs and Power supply: yes
Between Relay outputs and Interface: yes
Between easyNet and Power supply: yes
Between Digital inputs 24 V DC and easyNet: yes
Between Relay outputs and Digital inputs: yes
Between Relay outputs and easyNet: yes
Between Inputs and internal Power supply: Yes
Between Power supply and Outputs: yes
Between Digital inputs 24 V DC and Outputs: yes
Between easyNet and Inputs: yes
Between easyNet and Memory card: yes
Between Power supply and easyNet: yes
Between Relay outputs and easyLink: yes
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between easyNet and PC interface: yes
- !
- Protection of an Output relay - Fuse: 6 A gL/gG, Circuit-breaker with C characteristic: 4 A (only permissible with 24V DC), Short-circuit current IK: < 250 A
300 V AC, Between coil and contacts, According to EN 50178
Safety timing relay
Feedback circuit
Enabling switch
Protective door
Mode selection
OSSD input
Highest speed monitoring
According to EN 50156
Zero speed monitoring
Two-hand control
3 redundant relay outputs, 6 months test interval
Stopping in the event of an emergency
Cat. 4, Category
4.26 x 10-10, PFHd, Probability of failure per hour
SIL 3, Safety integrity level, In accordance with IEC 61508