View larger
S811+U42P3S 169873 Y7-169873 EATON ELECTRIC Soft starter, 3p, 420A, Eu 200-600VAC
S811+U42P3S
169873
Y7-169873
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configured as an Eaton Moeller S811+U42P3S soft starter, this high-current motor controller delivers smooth ramp-up and ramp-down control for large industrial loads. Electronic soft starters protect plant machinery and electrical infrastructure by mitigating high inrush currents and mechanical torque spikes.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 420 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 132 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 200 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
CE
UL 508
CCC
CSA
IEC/EN 60947-4-2
UL Category Control No.: NMFT
UL File No.: E202571
CSA22.2-14-1995
GB14048
UL
CSA File No.: LR 353
C-Tick
CSA Class No.: 3211-06
Features & Functions
Internal bypass
Motor overload protection
Internal bypass contacts
Current limitation
Potential isolation between power and control sections
Single direction
Min. ramp time 1 s - fast switching (semiconductor contactor)
Soft start function
Underload monitoring
Overload monitoring
Suppression of closing transients
General
NEMA Other
CLASS 10 (star-delta replacement)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
2 x (1 - 2.5) mm², Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
1 x (4 - 500 kcmil), Main cables
2 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
2 x (25 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables
Control circuit
150 mA, Control circuit, Digital inputs, External 24 V
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
Input/Output
24 V DC
Soft start function
Max. 2000 ms (Kickstart Duration)