S811+U42N3S 169870 S811PLUSU42N3S EATON ELECTRIC Soft starter, 420 A, 200 600 V AC, Us 24 V DC, Frame size U
S811+U42N3S
169870
S811PLUSU42N3S
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Electric soft starter delivers sophisticated motor management capabilities, protecting high-power assets from severe electrical and mechanical transients during startup. These units are extensively used in heavy industrial processes, processing plants, and large fluid management setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 420 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 132 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 200 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL Category Control No.: NMFT
UL File No.: E202571
CE
UL 508
CSA Class No.: 3211-06
CSA
UL
GB14048
CSA22.2-14-1995
CSA-C22.2 No. 14
C-Tick
CCC
IEC/EN 60947-4-2
Features & Functions
Internal bypass
Motor overload protection
Internal bypass contacts
Soft start function
Suppression of DC components for motors
Min. ramp time 1 s - fast switching (semiconductor contactor)
Potential isolation between power and control sections
Overload monitoring
Current limitation
Underload monitoring
Single direction
General
NEMA Other
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
CLASS 30 (6 x Iₑ for 30 s)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
1 x (70 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (70 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (4 - 500 kcmil), Main cables
2 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
Control circuit
1000 mA, Control circuit, Regulator supply
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
100 mA, Control circuit, Digital inputs, External 24 V (no-load)
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
100% (Kickstart voltage)