View larger
S811+U36P3S 169872 Y7-169872 EATON ELECTRIC Soft starter, 361 A, 200 600 V AC, Us 24 V DC, with control unit..
S811+U36P3S
169872
Y7-169872
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Supplied by Eaton Moeller, the S811+U36P3S is a soft starter configured to provide precise motor control and smooth acceleration characteristics in industrial settings. Equipment protection systems rely on this hardware to prevent abrupt mechanical shock and electrical strain across high-power circuits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 360 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 110 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 200 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP00
More info
▲General specifications
CSA File No.: LR 353
UL 508
CCC
UL
UL File No.: E202571
CSA-C22.2 No. 14
IEC/EN 60947-4-2
C-Tick
CSA
CSA Class No.: 3211-06
CE
GB14048
UL Category Control No.: NMFT
Features & Functions
Display
Internal bypass contacts
Motor overload protection
Suppression of closing transients
Underload monitoring
Single direction
Potential isolation between power and control sections
Soft start function
Overload monitoring
Suppression of DC components for motors
Current limitation
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Above 2000 m with 0.5 % derating per 100 m
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
Motor rating
Terminal capacities
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (25 - 240) mm², Main cables
1 x (14 - 12), Control circuit cables
2 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
1 x (70 - 150) mm², Main cables
Control circuit
150 mA, Control circuit, Digital inputs, External 24 V
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
1000 mA, Control circuit, Regulator supply
Input/Output
24 V DC (-10 %/+10 %)
Soft start function
Max. 2000 ms (Kickstart Duration)