View larger
S811+U36N3S 169869 S811PLUSU36N3S EATON ELECTRIC Soft starter, 361 A, 200 600 V AC, Us 24 V DC, Frame size U
S811+U36N3S
169869
S811PLUSU36N3S
EATON - MOELLER
1 Pcs.
Automation > Soft starter
High Performance Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for heavy-duty motor management, the S811+U36N3S 169869 S811PLUSU36N3S EATON ELECTRIC Soft starter, 361 A, 200 600 V AC, Us 24 V DC, Frame size U controls starting current and torque to prevent mechanical wear on heavy machinery. Industrial facilities deploy these controllers to ensure reliable, shock-free motor transitions across demanding production environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 360 A
- Rated operating voltage Ue (EF002418): 200 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 110 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 200 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): Yes
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 50 °C
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Integrated motor overload protection (EF007297): Yes
- Release class (EF006668): Adjustable
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
CSA22.2-14-1995
CE
CSA File No.: LR 353
C-Tick
CSA Class No.: 3211-06
UL File No.: E202571
CCC
CSA-C22.2 No. 14
GB14048
IEC/EN 60947-4-2
UL
UL 508
CSA
Features & Functions
Display
Internal bypass contacts
Motor overload protection
Min. ramp time 1 s - fast switching (semiconductor contactor)
Current limitation
Suppression of closing transients
Overload monitoring
Suppression of DC components for motors
Soft start function
Potential isolation between power and control sections
Single direction
General
NEMA Other
CLASS 30 (6 x Iₑ for 30 s)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s)
Climatic environmental conditions
Max. 2000 m
Damp heat, constant, to IEC 60068-2-3
Main conducting paths
Motor rating
Terminal capacities
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
2 x (1 - 2.5) mm², Control circuit cables
1 x (70 - 240) mm², Main cables
2 x (25 - 240) mm², Main cables
1 x (14 - 12), Control circuit cables
1 x (4 - 500 kcmil), Main cables
2 x (14 - 12), Control circuit cables
1 x (70 - 150) mm², Main cables
2 x (25 - 240) mm², Main cables
1 x (2.5 - 4) mm², Control circuit cables
Control circuit
1000 mA, Control circuit, Regulator supply
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
150 mA, Control circuit, Digital inputs, External 24 V
Input/Output
24 V DC
Soft start function
Max. 2000 ms (Kickstart Duration)