EATON - MOELLER SWD4-50LR8-24 SWD4-50LR8-24 116030 Y7-116030 EATON ELECTRIC Round cable, SmartWire-DT, 50m, 8-Pole, 8mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SWD4-50LR8-24 116030 Y7-116030 EATON ELECTRIC Round cable, SmartWire-DT, 50m, 8-Pole, 8mm

SWD4-50LR8-24

116030

Y7-116030

EATON - MOELLER

1 Pcs.

Round cable, SmartWire-DT, 50m, 8-Pole, 8mm SWD4-50LR8-24 Eaton SWD4 Round cable, SmartWire-DT, 50m, 8-Pole, 8mm 50 m, 8-pole, 8 mm diameter SmartWire-DT round cable for connecting the SmartWire-DT cards outside of the control panel, not assembled, for connection to SWD adapter SWD4-8FRF-10 as well as PCBs M22-SWD-Ix.

Cables > Data and communication cable
Smartwire Darwin

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton SWD4 Accessory Round cable
Catalog Number
116030
Model Code
SWD4-50LR8-24
EAN
4015081157709
Product Length/Depth
270 mm
Product Height
100 mm
Product Width
130 mm
Product Weight
4.03 kg
Certifications
CSA
UL
CSA File No.: 2324643
CSA Class No.: 3211-07
UL Category Control No.: NKCR
UL File No.: E29184
Catalog Notes
Condensation: permissible

Features & Functions

Features
Oil resistant (acc. EN 60811-404)
Oil resistant (acc. IEC 60811-404)
UV resistant
Functions
For connection to SWD4-8FRF-10 SWD cable adapter and M22-SWD-Ix series printed circuit boards

General

Cable length
50 m
Number of Poles
Eight-pole
Outer diameter - approximate
8.2 mm
Outer sheath material
Polyvinyl chloride (PVC)
Permitted bending radius, moving application with forced guidance - min
120 mm
Product category
SmartWire-DT accessories
Suitable as
Signaling cable

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C

Safety

Flame retardant
In accordance with EN 60332-1-2

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 116030 Cable (EC003249)
Feature Name Feature Value
Cable type (EF000081) Other
Duplex (EF023003) false
Conductor material (EF001622) Other
Conductor surface (EF010804) Bare
Diameter conductor (EF001621) 1.5 mm
Nominal cross section conductor (EF000060) 0.5 mm²
AWG size (EF011789) 20
Conductor category (EF001632) Class 2 = stranded
Number of cores (EF001792) 8
Number of stranding elements (EF001688) 4
Stranding element (EF001617) Pairs
Material core insulation (EF000061) Other
Specification core insulation (EF011805) Other
Core identification according to HD 308 S2 (EF013766) false
Core identification (EF000067) Colour
Screen over stranding element (EF001623) Foil
Stranding (EF003802) Bundle
Screen over stranding (EF001624) None
Longitudinal water blocking cable (EF011011) false
Radial water blocking cable (EF011012) false
Suitable for underground installation (EF003689) false
Approved type of underground installation (EF015176) Other
Protective sheath (EF001691) Other
Material outer sheath (EF001625) Polyvinyl chloride (PVC)
Specification material outer sheath (EF011806) Polypropylene (PP)
Colour outer sheath (EF001618) Green
Number of sheath layers (EF016997) 0
Armouring/reinforcement (EF001683) None
Material armouring (EF013440) Other
Cable geometry (EF013532) Round
Flame retardant according to IEC 60332-1-2 (EF016492) false
Flame retardant according to IEC 60332-3-21 (Cat A F/R) (EF016493) false
Flame retardant according to IEC 60332-3-22 (Cat A) (EF016494) false
Flame retardant according to IEC 60332-3-23 (Cat B) (EF016495) false
Flame retardant according to IEC 60332-3-24 (Cat C) (EF016496) false
Flame retardant according to IEC 60332-3-25 (Cat D) (EF016497) false
Low smoke according to EN IEC 61034-2 (EF003799) false
Halogen free according to EN IEC 60754-1 (EF016498) false
Halogen free according to EN IEC 60754-2 (EF003792) false
Halogen free according to EN IEC 60754-3 (EF016500) false
Reaction-to-fire according to EN 13501-6: Class (EF011577) None
Reaction-to-fire according to EN 13501-6: Smoke production (EF011578) None
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles (EF011579) None
Reaction-to-fire according to EN 13501-6: Acidity (EF011580) None
Circuit integrity according to IEC 60331-23 (EF016619) false
Oil resistant according to EN IEC 60811-404 (EF009770) true
Outer diameter approx. (EF003921) 8.2 mm
Min. permitted bending radius, moving application with forced guidance (EF011801) 120 mm
Min. permitted bending radius, moving application/free movement (EF011802) 120 mm
Min. permitted bending radius, stationary application/permanent installation (EF011803) 120 mm
Permitted cable outer temperature during assembling/handling (EF001685) -10 °C
Permitted cable outer temperature after assembling without vibration (EF001686) -20 °C
Category (EF001619) Other
NVP value (EF008387) 66.5 %
Certified for shipboard application (EF013772) false
Segregation class according to EN 50174-2 (EF013986)
Suitable as telephone cable (EF013768) false
Suitable as computer data cable (EF013769) false
Suitable as signalling cable (EF013770) true
Suitable for use as security alarm cable (EF017089) false
Drain wire (EF001029) false
With rip cord (EF017088) false
Cable width approx. (EF003796) 8.2 mm
Cable height approx. (EF003797) 100 mm
Weight (EF000167)
Characteristic impedance (EF001628) 100 Ohm
Max. tensile strength during installation (EF013801) None kN
Nominal voltage U (EF001615) 24 V
With rodent protection (EF007960) false
Circuit integrity according to DIN 4102-12 (EFDE0051)
Compatible with Grade2TV according to XP-C 90-483 (EFFR0001) false
Compatible with Grade3TV according to XP-C 90-483 (EFFR0002) false
Cable type according to BS 4737-3.30 (EFUK0022)
Rip cord colour according to BS 4737-3.30 (EFUK0023)
Compliant with BT (British Telecom) specification (EFUK0024)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.