EATON - MOELLER DIULEM/21/MV-G(24VDC) DIULEM/21/MV-G(24VDC) 214655 Y7-214655 EATON ELECTRIC Reversing contactor combination, 3p, +2S free, 4kW/400.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DIULEM/21/MV-G(24VDC) 214655 Y7-214655 EATON ELECTRIC Reversing contactor combination, 3p, +2S free, 4kW/400..

DIULEM/21/MV-G(24VDC)

214655

Y7-214655

EATON - MOELLER

1 Pcs.

Reversing contactor combination, 3p, +2S free, 4kW/400V/AC3 DIULEM/21/MV-G(24VDC) Eaton Moeller® series DIULE Reversing contactor combination, 380 V 400 V: 4 kW, 24 V DC, DC operation Reversing contactor combination, Application: Contactor combinations for starting motors with two directions of rotation, Accessories: DIUL reversing combinations, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Rated operational current AC-3 380 V 400 V: Ie= 9 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 2.2 kW, 380 V 400 V: P= 4 kW, 660 V 690 V: P= 4 kW, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Notes: Also suitable for motors with efficiency class IE3. , IE3-ready devices are identified by the logo on their packaging.

Automation > Combination of contactors
Contactors up to 170A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series DIULE contactor combination
Catalog Number
214655
Model Code
DIULEM/21/MV-G(24VDC)
EAN
4015082146559
Product Length/Depth
94 mm
Product Height
61 mm
Product Width
90 mm
Product Weight
0.53 kg
Certifications
CSA
CE
CSA Class No.: 3211-04
CSA-C22.2 No. 60947-4-1-14
IEC/EN 60947-4-1
CSA File No.: 012528
UL 60947-4-1
UL
UL Category Control No.: NLDX
UL File No.: E29096

Features & Functions

Features
Mechanical interlock
Functions
Reversing safety
Number Of Poles
Three-pole

General

Application
Contactor combinations for starting motors with two directions of rotation
Overvoltage category
III
Pollution degree
3
Product category
Contactor combinations
Suitable for
Also motors with efficiency class IE3
Utilization category
AC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage type
DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C

Electro Magnetic Compatibility

Interference immunity
According to EN 60947-1

Electrical Rating

Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
9 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
9 A
Rated insulation voltage (Ui)
690 V
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
9 A
Rated operational power at AC-3, 380/400 V, 50 Hz
4 kW
Rated operational power at AC-4, 220/230 V, 50 Hz
1.5 kW
Rated operational power at AC-4, 660/690 V, 50 Hz
3 kW

Magnet system

Duty factor
100 %
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
24 V

Communication

Connection
Screw terminals

Contacts

Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
2

Design verification

Equipment heat dissipation, current-dependent Pvid
2.13 W
Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
9 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 214655 Low-voltage industrial controls and switchgear (EC000010)
Feature Name Feature Value
Function (EF000030) Reversing safety
Suitable for rail mounting (EF003972) No
Rated control supply voltage AC 50 Hz (EF003978) 0 V
Rated control supply voltage AC 60 Hz (EF003979) 0 V
Rated control supply voltage DC (EF003980) 24 V
Voltage type for actuating (EF008242) DC
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 6
Type of electrical connection of main circuit (EF006819) Screw connection
Voltage type (operating voltage) (EF005294) AC
Operating voltage AC 50 Hz (EF008206) 24 V
Operating voltage AC 60 Hz (EF008207) 24 V
Operating voltage DC (EF008208) 0 V
Rated operation current Ie at AC-1, 400 V (EF001393) 9 A
Rated operation current Ie at AC-3, 400 V (EF001392) 9 A
Rated operation power at AC-3, 400 V (EF001364) 4 kW
Rated operation power NEMA (EF011960) 3.7 kW
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 2
Number of auxiliary contacts as change-over contact (EF003531) 0
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other
Width (EF000008) 90 mm
Height (EF000040) 61 mm
Depth (EF000049) 94 mm

Product Datasheet