View larger
DIULM50/11(110V50HZ,120V60HZ) 278233 Y7-278233 EATON ELECTRIC Reversing contactor combination, 3p, 22kW/400V..
DIULM50/11(110V50HZ,120V60HZ)
278233
Y7-278233
EATON - MOELLER
1 Pcs.
Automation > Combination of contactors
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Reversing contactor combination by Eaton Moeller, designated as DIULM50/11(110V50HZ,120V60HZ), coordinates bidirectional motor movement in industrial drive applications. These pre-wired assemblies prevent simultaneous forward and reverse closing through reliable mechanical and electrical interlocks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Function (EF000030): Reversing safety
- Suitable for rail mounting (EF003972): No
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 120 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 6
- Type of electrical connection of main circuit (EF006819): Screw connection
- Voltage type (operating voltage) (EF005294): AC
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Operating voltage DC (EF008208): 0 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 50 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 50 A
- Rated operation power at AC-3, 400 V (EF001364): 22 kW
- Rated operation power NEMA (EF011960): 29.8 kW
More info
▲General specifications
UL
CSA
CE
UL 60947-4-1
UL File No.: E29096
UL Category Control No.: NLDX
CSA Class No.: 2411-03, 3211-04
CSA File No.: 012528
IEC/EN 60947-4-1
Features & Functions
General
AC-3: Normal AC induction motors: starting, switch off during running