The Eaton Moeller PFDM-125/4/01 is a residual current circuit breaker (RCCB) designed to protect electrical installations against earth leakage faults and potential shock hazards. Devices of this type are commonly installed in commercial and industrial distribution boards to automatically disconnect circuits when residual currents exceed safe thresholds. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Rated voltage (EF000228): 400 V
- Rated current (EF000227): 125 A
- Rated fault current (EF002358): 0.1 A
- Mounting method (EF000003): DIN rail
- Leakage current type (EF002560): AC
- Selective protection (EF002561): No
- Short-time delayed tripping (EF003604): No
- Short-circuit breaking capacity (Icw) (EF002562): 10 kA
- Surge current capacity (EF002564): 0.2 kA
- With interlocking device (EF007385): No
- Frequency (EF005455): 50 Hz
- Additional equipment possible (EF008148): Yes
- Degree of protection (IP) (EF005474): IP20
- Width in number of modular spacings (EF002950): 4
- Built-in depth (EF000218): 71.5 mm
More info
▲Delivery program
Switching elements according to EN 50005
Switching elements according to EN 50012 are to be preferred.
Version E combinations correspond to EN 50011 and are to be preferred.
DILEM-01(-G)(…)
DILEM-4(-G)(…)
DILER40(-G)
DILER31(-G)
DILER22
DILEEM-10(-G)(…)
DILEEM-01(-G)(…)
DILEM12-10(-G)(…)
DILEM12-01(-G)(…)
Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open)
Technical data
Damp heat, cyclic, to IEC 60068-2-30
2 x (0.75 - 2.5) mm2
2 x (0.75 - 1.5) mm2
1 x 6 mm
(at Ue= 24 V DC, Umin= 17 V, Imin= 5.4 mA) λ
Design verification as per IEC/EN 61439
Technical data ETIM 7.0
Approvals
Characteristics
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
Time interval between two loading cycles: 15 minutes
Dimensions
86 mm: DILE…-C... + …DILE(M)