EATON - MOELLER PFDM-125/2/03 PFDM-125/2/03 249033 EATON ELECTRIC Residual current circuit breaker (RCCB), 125A, 2p, 300mA, type AC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PFDM-125/2/03 249033 EATON ELECTRIC Residual current circuit breaker (RCCB), 125A, 2p, 300mA, type AC

PFDM-125/2/03

249033

EATON - MOELLER

1 Pcs.

Residual current circuit breaker (RCCB), 125A, 2p, 300mA, type AC Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, Auxiliary contact, selective part no.Suitable for use in the free (on-site power and outdoor distribution board) to -25 °C, mains-voltage-independent tripping, can be used for people and additional protection

Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Residual current circuit breaker (RCCB), 125A, 2p, 300mA, type AC
Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, Auxiliary contact, selective part no.Suitable for use in the free (on-site power and outdoor distribution board) to -25 °C, mains-voltage-independent tripping, can be used for people and additional protection
[

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
125 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
30 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
Starting at 40 °C, the max. permissible continuous current decreases by 1.8% for every 1 °C
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
2
Rated voltage
230 V
Rated current
125 A
Rated fault current
300 mA
Rated insulation voltage Ui
400 V
Rated impulse withstand voltage Uimp
4 kV
Mounting method
DIN rail
Leakage current type
AC
Selective protection
No
Short-time delayed tripping
No
Short-circuit breaking capacity (Icw)
10 kA
Surge current capacity
0.2 kA
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Yes
Degree of protection (IP)
IP20
Width in number of modular spacings
2
Built-in depth
71.5 mm
Ambient temperature during operating
-25 - 40 °C
Pollution degree
2
Connectable conductor cross section multi-wired
1.5 - 16 mm²
Connectable conductor cross section solid-core
1.5 - 50 mm²
]

ETIM for 249033 Circuit breakers and fuses (EC000003)
Feature Name Feature Value
Number of poles (EF001391) 2
Rated voltage (EF000228) 230 V
Rated current (EF000227) 125 A
Rated fault current (EF002358) 0.3 A
Mounting method (EF000003) DIN rail
Leakage current type (EF002560) AC
Selective protection (EF002561) No
Short-time delayed tripping (EF003604) No
Short-circuit breaking capacity (Icw) (EF002562) 10 kA
Surge current capacity (EF002564) 0.2 kA
With interlocking device (EF007385) No
Frequency (EF005455) 50 Hz
Additional equipment possible (EF008148) Yes
Degree of protection (IP) (EF005474) IP20
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 71.5 mm
Ambient temperature during operating (EF007515) -25 °C
Explosion-proof (EF004663) No

Product Datasheet