EATON - MOELLER FI-80/4/03-S/B FI-80/4/03-S/B 281024 EATON ELECTRIC Residual current circuit-breaker, 80A, 4p, 3A, B-Char View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FI-80/4/03-S/B 281024 EATON ELECTRIC Residual current circuit-breaker, 80A, 4p, 3A, B-Char

FI-80/4/03-S/B

281024

EATON - MOELLER

1 Pcs.

Residual current circuit-breaker, 80A, 4p, 3A, B-Char Residual current circuit-breaker FI, 4 pole, Rated current In: 80 A, Rated short-circuit strength Icn: 10 kA, Rated fault current IΔN: 0.3 A

Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Designed for heavy-duty power distribution safety, an Eaton Moeller FI-80/4/03-S/B residual current circuit-breaker protects electrical circuits from earth leakage faults by tripping when differential current limits are exceeded.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current: I n
  • Rated short-circuit strength: I cn
  • Rated fault current: I ΔN
  • Rated operating voltage: U e
  • Rated frequency: f
  • Rated fault currents: I Δn
  • Rated non-tripping current: IΔno
  • Rated fault switching capacity: I Δm
  • Rated switching capacity: I cn
  • Rated current: I e
  • Rated impulse withstand voltage: U imp
  • Number of poles (EF001391): 4
  • Rated voltage (EF000228): 400 V
  • Rated current (EF000227): 80 A
  • Rated fault current (EF002358): 0.3 A
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV

More info

▲
Delivery program
Basic function
Residual current circuit-breakers
Number of poles
4 pole
Rated current
In A 80
Rated short-circuit strength
Icn kA 10
Rated fault current
IΔN A 0.3
Type
Type S/B
Tripping
s… selective switch off
Product range
FI
Sensitivity
All current sensitive
Impulse withstand current
surge-proof 5 kA
Technical data
Electrical
Standards
IEC/EN 61008
Tripping
s… selective switch off
Rated operating voltage
Ue V AC 230/400
Limit values of the operating voltage
V AC 184 … 440
Rated frequency
f Hz 50
Rated fault currents
IΔn mA 30, 100, 300, 500
Rated non-tripping current
IΔno 0.5 x I∆n
Rated fault switching capacity
Rated fault switching capacity
IΔm A In = 40 A: 500
In = 63 A: 630
In = 80 A: 800
In = 100 A: 1000
In= 125 A: 1250
Sensitivity
Pulsed current and AC/DC
Rated switching capacity
Icn kA 10
Rated current
Ie A 80
Rated impulse withstand voltage
Uimp kV 4
Maximum max. as short-circuit protective device
A gL In < 80 A: 100
In= 80 A: 125
In= 125 A: 125
Lifespan
S
Electrical
Operations > 2000
Mechanical
Operations > 5000
Mechanical
Standard front dimension
mm 45
Enclosure height
mm 85
Terminal protection
Protection against electric shock to IEC 536
Mounting width
mm 70 (4 space unit)
Mounting
Top-hat rail IEC/EN 60715
Degree of protection
Integrated
IP40
Terminals top and bottom
Twin-purpose terminals
Terminal capacities
mm2
Solid
mm2 1.5 - 50; 2 x (1.5 - 16)
Stranded
mm2 1.5 - 50; 2 x (1.5 - 16)
flexible
mm2 1.5 - 50; 2 x (1.5 - 16)
Thickness of busbar material
mm 0.8 … 2
Admissible ambient temperature range
°C -25 … +40
Climatic proofing
IEC/EN 61008
Technical data ETIM 7.0(Show features)(Hide features)
Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
4
Rated voltage
V 400
Rated current
A 80
Rated fault current
mA 300
Rated insulation voltage Ui
V 400
Rated impulse withstand voltage Uimp
kV 4
Mounting method
DIN rail
Leakage current type
B
Selective protection
Yes
Short-time delayed tripping
Yes
Short-circuit breaking capacity (Icw)
kA 10
Surge current capacity
kA 5
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Yes
Degree of protection (IP)
IP20
Width in number of modular spacings
4
Built-in depth
mm 69.5
Ambient temperature during operating
°C -25 - 55
Pollution degree
2
Connectable conductor cross section multi-wired
mm² 1.5 - 16
Connectable conductor cross section solid-core
mm² 1.5 - 35

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.