EATON - MOELLER PFDM-125/4/03-S/A PFDM-125/4/03-S/A 285639 EATON ELECTRIC Residual current circuit-breaker, 125A, 4p, 3mA, A-Char View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PFDM-125/4/03-S/A 285639 EATON ELECTRIC Residual current circuit-breaker, 125A, 4p, 3mA, A-Char

PFDM-125/4/03-S/A

285639

EATON - MOELLER

1 Pcs.

Residual current circuit-breaker, 125A, 4p, 3mA, A-Char Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, auxiliary contact selective part no., suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Residual current circuit-breaker, 125A, 4p, 3mA, A-Char
Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, auxiliary contact selective part no., suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C
[

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
125 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
33.6 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
Starting at 40 °C, the max. permissible continuous current decreases by 1.8% for every 1 °C
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
4
Rated voltage
400 V
Rated current
125 A
Rated fault current
300 mA
Rated insulation voltage Ui
440 V
Rated impulse withstand voltage Uimp
4 kV
Mounting method
DIN rail
Leakage current type
A
Selective protection
Yes
Short-time delayed tripping
No
Short-circuit breaking capacity (Icw)
10 kA
Surge current capacity
5 kA
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Yes
Degree of protection (IP)
IP20
Width in number of modular spacings
4
Built-in depth
71.5 mm
Ambient temperature during operating
-25 - 40 °C
Pollution degree
2
Connectable conductor cross section multi-wired
1.5 - 16 mm²
Connectable conductor cross section solid-core
1.5 - 50 mm²
]

ETIM for 285639 Circuit breakers and fuses (EC000003)
Feature Name Feature Value
Number of poles (EF001391) 4
Rated voltage (EF000228) 400 V
Rated current (EF000227) 125 A
Rated fault current (EF002358) 0.3 A
Mounting method (EF000003) DIN rail
Leakage current type (EF002560) A
Selective protection (EF002561) Yes
Short-time delayed tripping (EF003604) No
Short-circuit breaking capacity (Icw) (EF002562) 10 kA
Surge current capacity (EF002564) 5 kA
With interlocking device (EF007385) No
Frequency (EF005455) 50 Hz
Additional equipment possible (EF008148) Yes
Degree of protection (IP) (EF005474) IP20
Width in number of modular spacings (EF002950) 4
Built-in depth (EF000218) 71.5 mm
Ambient temperature during operating (EF007515) -25 °C
Explosion-proof (EF004663) No