EATON - MOELLER PFDM-125/4/03-S/A PFDM-125/4/03-S/A 285639 EATON ELECTRIC Residual current circuit-breaker, 125A, 4p, 3mA, A-Char View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PFDM-125/4/03-S/A 285639 EATON ELECTRIC Residual current circuit-breaker, 125A, 4p, 3mA, A-Char

PFDM-125/4/03-S/A

285639

EATON - MOELLER

1 Pcs.

Residual current circuit-breaker, 125A, 4p, 3mA, A-Char Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, auxiliary contact selective part no., suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller PFDM-125/4/03-S/A residual current circuit-breaker provides selective fault protection in extensive industrial power distribution grids, allowing upstream and downstream protective devices to coordinate effectively. It trips upon detecting significant earth leakage currents to prevent electrical hazards.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 4
  • Rated voltage (EF000228): 400 V
  • Rated current (EF000227): 125 A
  • Rated fault current (EF002358): 0.3 A
  • Mounting method (EF000003): DIN rail
  • Leakage current type (EF002560): A
  • Selective protection (EF002561): Yes
  • Short-time delayed tripping (EF003604): No
  • Short-circuit breaking capacity (Icw) (EF002562): 10 kA
  • Surge current capacity (EF002564): 5 kA
  • With interlocking device (EF007385): No
  • Frequency (EF005455): 50 Hz
  • Additional equipment possible (EF008148): Yes
  • Degree of protection (IP) (EF005474): IP20
  • Width in number of modular spacings (EF002950): 4
  • Built-in depth (EF000218): 71.5 mm

More info

▲
Residual current circuit-breaker, 125A, 4p, 3mA, A-Char
Modern residual current circuit-breaker for rated 125 A current range, for fault and additional protection, auxiliary contact selective part no., suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C
[

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
125 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
33.6 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
Starting at 40 °C, the max. permissible continuous current decreases by 1.8% for every 1 °C
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
4
Rated voltage
400 V
Rated current
125 A
Rated fault current
300 mA
Rated insulation voltage Ui
440 V
Rated impulse withstand voltage Uimp
4 kV
Mounting method
DIN rail
Leakage current type
A
Selective protection
Yes
Short-time delayed tripping
No
Short-circuit breaking capacity (Icw)
10 kA
Surge current capacity
5 kA
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Yes
Degree of protection (IP)
IP20
Width in number of modular spacings
4
Built-in depth
71.5 mm
Ambient temperature during operating
-25 - 40 °C
Pollution degree
2
Connectable conductor cross section multi-wired
1.5 - 16 mm²
Connectable conductor cross section solid-core
1.5 - 50 mm²
]

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.