View larger
RASP5-8422EIP-412R001S1 198918 Y7-198918 EATON ELECTRIC RASP5-8422EIP-412R001S1
RASP5-8422EIP-412R001S1
198918
Y7-198918
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Variable frequency drive RASP5-8422EIP-412R001S1 by Eaton Moeller serves as a decentralized motor controller designed to operate asynchronous motors efficiently. These integrated drive systems combine switching and control logic to streamline machine wiring and automation architectures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
UL approval
IEC/EN 61800-5-1
UL 61800-5-1
Features & Functions
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Internal and on heat sink, temperature-controlled Fan
Parameterization: Keypad
Key switch position OFF/RESET
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
IGBT inverter
Key switch position AUTO
Fan
2 Actuator outputs
PC connection
Manual override switch
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
PTC thermistor monitoring
1 potentiometer speed
3 fixed speeds
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
AC voltage
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, Off-delay
Sensorless vector control (SLV)
PM and LSPM motors
Synchronous reluctance motors
BLDC motors
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
AC voltage
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
230/277 V AC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length