RASP5-8421PNT-412R111S1 199057 Y7-199057 EATON ELECTRIC RASP5-8421PNT-412R111S1
RASP5-8421PNT-412R111S1
199057
Y7-199057
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller RASP5-8421PNT-412R111S1 is an advanced frequency converter engineered for precise motor speed regulation and operational efficiency in automated machine setups. Variable frequency drives are typically implemented to control AC motor dynamics, optimize energy consumption, and provide smooth acceleration and deceleration across various industrial mechanical processes.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): true
- Application in industrial area permitted (EF007294): true
More info
▲General specifications
UL 61800-5-1
CE
RoHS
UL approval
Features & Functions
Internal and on heat sink, temperature-controlled Fan
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Fan
2 Actuator outputs
Key switch position OFF/RESET
PTC thermistor monitoring
Key switch position AUTO
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
IGBT inverter
Braking resistance
Breaking resistance
Manual override switch
Key switch position HAND
Thermo-click with safe isolation
Internal DC link
PC connection
Selector switch (Positions: REV - OFF - FWD)
For actuation of motors with mechanical brake
STO (Safe Torque Off)
Brake chopper with braking resistance for dynamic braking
3 fixed speeds
1 potentiometer speed
General
NEMA 12
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, On-delay
Synchronous reluctance motors
Sensorless vector control (SLV)
U/f control
BLDC motors
At 40 °C
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Number of slave addresses: 31 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length