View larger
RASP5-8420PNT-412R001S1 199044 Y7-199044 EATON ELECTRIC RASP5-8420PNT-412R001S1
RASP5-8420PNT-412R001S1
199044
Y7-199044
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller RASP5-8420PNT-412R001S1 decentralised drive unit manages motor operations locally on plant floors, reducing cabling complexity in distributed automation networks. Such units integrate power conversion and communication features into a compact housing mounted near the target machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): true
- Application in industrial area permitted (EF007294): true
More info
▲General specifications
CE
RoHS
IEC/EN 61800-5-1
UL 61800-5-1
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Parameterization: Fieldbus
Internal and on heat sink, temperature-controlled Fan
Key switch position AUTO
Internal DC link
PC connection
Fan
Key switch position HAND
PTC thermistor monitoring
2 Actuator outputs
Control unit
Manual override switch
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
Key switch position OFF/RESET
Thermo-click with safe isolation
1 potentiometer speed
General
NEMA 12
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
BLDC motors
PM and LSPM motors
Synchronous reluctance motors
Sensorless vector control (SLV)
At 40 °C
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length