View larger
RASP5-8404A31-412R101S1 198859 Y7-198859 EATON ELECTRIC RASP5-8404A31-412R101S1
RASP5-8404A31-412R101S1
198859
Y7-198859
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for decentralized automation tasks, the Eaton Moeller RASP5-8404A31-412R101S1 acts as a robust variable frequency drive designed to regulate three-phase motor speeds directly on machinery or transport equipment. Such devices provide precise operational control and integrate seamlessly into industrial control networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
UL 61800-5-1
UL approval
CE
Features & Functions
Parameterization: drivesConnect
Diagnostics and reset on device and via AS-Interface
Internal and on heat sink, temperature-controlled Fan
Parameterization: Keypad
Parameterization: Fieldbus
Internal DC link
Breaking resistance
IGBT inverter
Manual override switch
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Key switch position AUTO
Braking resistance
Fan
PTC thermistor monitoring
Key switch position HAND
Control unit
PC connection
Key switch position OFF/RESET
Thermo-click with safe isolation
Brake chopper with braking resistance for dynamic braking
1 potentiometer speed
3 fixed speeds
4-quadrant operation possible
General
NEMA 12
AS-Interface profile cable: S-7.4 for 31 modules
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, Off-delay
Synchronous reluctance motors
U/f control
PM and LSPM motors
Sensorless vector control (SLV)
At 40 °C
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
400/480 V AC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length