View larger
RASP5-8404A31-412R001S1 198855 Y7-198855 EATON ELECTRIC RASP5-8404A31-412R001S1
RASP5-8404A31-412R001S1
198855
Y7-198855
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller RASP5-8404A31-412R001S1 is an integrated drive solution built to streamline motor management and speed regulation within decentralized automation architectures. Devices of this type are commonly mounted directly on or near machinery like conveyors and sorting systems to minimize central cabinet space and reduce wiring complexity. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
UL approval
CE
RoHS
Features & Functions
Parameterization: Keypad
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect mobile (App)
Internal and on heat sink, temperature-controlled Fan
Parameterization: Fieldbus
IGBT inverter
Manual override switch
Key switch position OFF/RESET
Key switch position HAND
Fan
PTC thermistor monitoring
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
Control unit
PC connection
Thermo-click with safe isolation
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
3 fixed speeds
1 potentiometer speed
General
IP65
AS-Interface profile cable: S-7.4 for 31 modules
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
AC voltage
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, On-delay
BLDC motors
Synchronous reluctance motors
Sensorless vector control (SLV)
PM and LSPM motors
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
AC voltage
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length