View larger
RASP5-8404A31-4120111S1 198851 Y7-198851 EATON ELECTRIC RASP5-8404A31-4120111S1
RASP5-8404A31-4120111S1
198851
Y7-198851
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller frequency inverter RASP5-8404A31-4120111S1 controls three-phase electric motors to optimize performance and reduce energy consumption in automated production lines. Inverter drives allow operators to dynamically adjust motor speeds and torque profiles to match varying operational demands.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL approval
CE
IEC/EN 61800-5-1
RoHS
Features & Functions
Internal and on heat sink, temperature-controlled Fan
Parameterization: Keypad
Diagnostics and reset on device and via AS-Interface
Parameterization: drivesConnect
Parameterization: Fieldbus
Internal DC link
Breaking resistance
Selector switch (Positions: REV - OFF - FWD)
Braking resistance
Thermo-click with safe isolation
Key switch position OFF/RESET
PTC thermistor monitoring
Control unit
PC connection
IGBT inverter
Key switch position HAND
Fan
Key switch position AUTO
Brake chopper with braking resistance for dynamic braking
4-quadrant operation possible
1 potentiometer speed
STO (Safe Torque Off)
3 fixed speeds
General
IP65
AS-Interface profile cable: S-7.4 for 31 modules
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
AC voltage
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, Off-delay
BLDC motors
Synchronous reluctance motors
U/f control
PM and LSPM motors
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
AC voltage
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length