View larger
RASP5-8402A31-512R101S1 198588 Y7-198588 EATON ELECTRIC RASP5-8402A31-512R101S1
RASP5-8402A31-512R101S1
198588
Y7-198588
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller RASP5-8402A31-512R101S1 is an advanced frequency converter engineered for regulating motor speeds in automated installations and manufacturing lines. Frequency converters dynamically manage electrical frequency and voltage supplied to electric motors, allowing precise control over operational velocity, torque, and energy efficiency across various industrial machinery setups.
Exact pricing, availability, and lead times are confirmed per enquiry through our RFQ service.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
IEC/EN 61800-5-1
UL approval
UL 61800-5-1
Features & Functions
Diagnostics and reset on device and via AS-Interface
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Parameterization: drivesConnect
PC connection
Key switch position AUTO
Braking resistance
Control unit
Breaking resistance
Key switch position OFF/RESET
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
PTC thermistor monitoring
IGBT inverter
Manual override switch
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
For actuation of motors with mechanical brake
3 fixed speeds
1 potentiometer speed
4-quadrant operation possible
General
IP65
ASI
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
< 95 %, no condensation
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, On-delay
Sensorless vector control (SLV)
PM and LSPM motors
Synchronous reluctance motors
BLDC motors
At 40 °C
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
Center-point earthed star network (TN-S network)
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length