View larger
RASP5-8401A31-512R101S1 198835 Y7-198835 EATON ELECTRIC RASP5-8401A31-512R101S1
RASP5-8401A31-512R101S1
198835
Y7-198835
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller RASP5-8401A31-512R101S1 is a variable frequency drive built to manage electric motor dynamics across heavy-duty commercial applications. Motor controllers regulate rotational speeds, optimize power consumption, and protect driven equipment from mechanical overload. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
CE
UL approval
IEC/EN 61800-5-1
Features & Functions
Parameterization: drivesConnect
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Internal and on heat sink, temperature-controlled Fan
Parameterization: Fieldbus
PC connection
Key switch position AUTO
Key switch position HAND
Selector switch (Positions: REV - OFF - FWD)
Fan
Breaking resistance
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Control unit
Manual override switch
Key switch position OFF/RESET
Internal DC link
IGBT inverter
Thermo-click with safe isolation
PTC thermistor monitoring
3 fixed speeds
4-quadrant operation possible
Brake chopper with braking resistance for dynamic braking
1 potentiometer speed
General
NEMA 12
ASI
C1: for conducted emissions only
AC voltage
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, Off-delay
U/f control
Sensorless vector control (SLV)
BLDC motors
Synchronous reluctance motors
At 40 °C
480 V AC, 3-phase
AC voltage
Center-point earthed star network (TN-S network)
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C2 ≤ 5 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length