View larger
RASP5-8401A31-4120101S1 198841 Y7-198841 EATON ELECTRIC RASP5-8401A31-4120101S1
RASP5-8401A31-4120101S1
198841
Y7-198841
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller built the RASP5-8401A31-4120101S1 frequency converter to manage industrial motor operations efficiently across complex electrical frameworks. Industrial facilities rely on these electronic controllers to adjust operational speeds and maintain steady performance under varying mechanical loads.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
IEC/EN 61800-5-1
UL approval
RoHS
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Breaking resistance
Key switch position AUTO
Internal DC link
PC connection
Selector switch (Positions: REV - OFF - FWD)
Key switch position OFF/RESET
Key switch position HAND
Control unit
Fan
IGBT inverter
PTC thermistor monitoring
Braking resistance
Thermo-click with safe isolation
1 potentiometer speed
Brake chopper with braking resistance for dynamic braking
For actuation of motors with mechanical brake
4-quadrant operation possible
General
NEMA 12
ASI
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Center-point earthed star network (TN-S network)
AC voltage
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.8 - 8.5 A, motor, main circuit
< 10 ms, Off-delay
PM and LSPM motors
U/f control
Sensorless vector control (SLV)
Synchronous reluctance motors
At 40 °C
400 V AC, 3-phase
Center-point earthed star network (TN-S network)
AC voltage
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
180/207 V DC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length