View larger
RASP5-8400A31-512R001S1 198584 Y7-198584 EATON ELECTRIC RASP5-8400A31-512R001S1
RASP5-8400A31-512R001S1
198584
Y7-198584
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Housed within automated environments, this Eaton Moeller RASP5-8400A31-512R001S1 variable frequency drive delivers adjustable motor control by regulating frequency and voltage supply. Such units drive conveyors, pumps, and fans to match output dynamically with real-time operational demands.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 8.5 A
- Power consumption (EF000346): 95 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL approval
UL 61800-5-1
IEC/EN 61800-5-1
RoHS
Features & Functions
Internal, temperature-controlled Fan
Parameterization: Fieldbus
Diagnostics and reset on device and via AS-Interface
Parameterization: Keypad
Parameterization: drivesConnect
Internal DC link
Manual override switch
Thermo-click with safe isolation
Fan
Control unit
PTC thermistor monitoring
Selector switch (Positions: REV - OFF - FWD)
PC connection
IGBT inverter
Key switch position AUTO
Key switch position HAND
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
1 potentiometer speed
General
NEMA 12
ASI
C1: for conducted emissions only
AC voltage
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
Synchronous reluctance motors
BLDC motors
PM and LSPM motors
Sensorless vector control (SLV)
For 60 s every 600 s
480 V AC, 3-phase
AC voltage
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Number of slave addresses: 31 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length