View larger
RASP5-5424PNT-412R110S1 199027 Y7-199027 EATON ELECTRIC RASP5-5424PNT-412R110S1
RASP5-5424PNT-412R110S1
199027
Y7-199027
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Dynamic speed control and efficient power management for automated systems are delivered by the Eaton Moeller RASP5-5424PNT-412R110S1 variable frequency drive. These robust units adapt electrical supplies to match varying mechanical loads, reducing energy usage and minimizing stress on system components.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): true
- Application in industrial area permitted (EF007294): true
More info
▲General specifications
RoHS
CE
IEC/EN 61800-5-1
UL approval
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Selector switch (Positions: REV - OFF - FWD)
Internal DC link
PC connection
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
Control unit
Key switch position OFF/RESET
2 Actuator outputs
PTC thermistor monitoring
Breaking resistance
Key switch position AUTO
IGBT inverter
Manual override switch
Braking resistance
Brake chopper with braking resistance for dynamic braking
For actuation of motors with mechanical brake
3 fixed speeds
4-quadrant operation possible
STO (Safe Torque Off)
General
NEMA 12
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
AC voltage
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: According to IEC/EN 60068-2-6
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
BLDC motors
U/f control
Sensorless vector control (SLV)
Synchronous reluctance motors
For 60 s every 600 s
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
AC voltage
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
400/480 V AC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length