View larger
RASP5-5422EIP-412R110S1 198914 Y7-198914 EATON ELECTRIC RASP5-5422EIP-412R110S1
RASP5-5422EIP-412R110S1
198914
Y7-198914
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for decentralized automation environments, the Eaton Moeller RASP5-5422EIP-412R110S1 unit provides integrated motor starting and frequency conversion close to the actuating load. Decentralized drives simplify cabling and improve control response in complex material handling and packaging systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
RoHS
UL approval
IEC/EN 61800-5-1
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Key switch position AUTO
Manual override switch
Braking resistance
Internal DC link
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Control unit
Key switch position OFF/RESET
Selector switch (Positions: REV - OFF - FWD)
PTC thermistor monitoring
PC connection
IGBT inverter
Key switch position HAND
Thermo-click with safe isolation
2 Actuator outputs
STO (Safe Torque Off)
3 fixed speeds
1 potentiometer speed
4-quadrant operation possible
Brake chopper with braking resistance for dynamic braking
General
IP65
C1: for conducted emissions only
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
PM and LSPM motors
Sensorless vector control (SLV)
BLDC motors
Synchronous reluctance motors
At 40 °C
480 V AC, 3-phase
Center-point earthed star network (TN-S network)
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
230/277 V AC (external brake 50/60 Hz)
Communication
Specification: S-7.4 (AS-Interface®)
Number of slave addresses: 31 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length