View larger
RASP5-5422EIP-412R010S1 198910 Y7-198910 EATON ELECTRIC RASP5-5422EIP-412R010S1
RASP5-5422EIP-412R010S1
198910
Y7-198910
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller frequency converter, part number RASP5-5422EIP-412R010S1, serves as a crucial component for varying the operational speed of three-phase AC motors in manufacturing plants and automated systems. Such devices dynamically match motor output to load demands, reducing energy consumption and mechanical wear.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
UL approval
UL 61800-5-1
IEC/EN 61800-5-1
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Control unit
Key switch position AUTO
Key switch position OFF/RESET
Key switch position HAND
PC connection
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
Thermo-click with safe isolation
IGBT inverter
2 Actuator outputs
Internal DC link
PTC thermistor monitoring
STO (Safe Torque Off)
For actuation of motors with mechanical brake
1 potentiometer speed
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
AC voltage
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, Off-delay
BLDC motors
PM and LSPM motors
Sensorless vector control (SLV)
U/f control
At 40 °C
400 V AC, 3-phase
AC voltage
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Specification: S-7.4 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length