View larger
RASP5-5421PNT-412R010S1 199021 Y7-199021 EATON ELECTRIC RASP5-5421PNT-412R010S1
RASP5-5421PNT-412R010S1
199021
Y7-199021
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller frequency converter, part number RASP5-5421PNT-412R010S1, is utilized to regulate the speed and torque of AC motors in demanding commercial and industrial machinery installations. Drives of this type provide precise frequency and voltage adjustments to optimize motor efficiency and process control.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL approval
IEC/EN 61800-5-1
RoHS
UL 61800-5-1
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Parameterization: Fieldbus
Key switch position AUTO
PTC thermistor monitoring
Control unit
Key switch position OFF/RESET
Manual override switch
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Internal DC link
Thermo-click with safe isolation
IGBT inverter
Key switch position HAND
Selector switch (Positions: REV - OFF - FWD)
2 Actuator outputs
1 potentiometer speed
STO (Safe Torque Off)
For actuation of motors with mechanical brake
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
AC voltage
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, On-delay
Synchronous reluctance motors
BLDC motors
Sensorless vector control (SLV)
U/f control
For 60 s every 600 s
400 V AC, 3-phase
AC voltage
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length