View larger
RASP5-5421PNT-4120110S1 199009 Y7-199009 EATON ELECTRIC RASP5-5421PNT-4120110S1
RASP5-5421PNT-4120110S1
199009
Y7-199009
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Advanced motor control devices manage rotational velocity and torque profiles to match exact operational criteria in automated machinery. The Eaton Moeller RASP5-5421PNT-4120110S1 unit is built to withstand rigorous industrial environments while maintaining precise speed control.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
CE
UL 61800-5-1
IEC/EN 61800-5-1
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Parameterization: Fieldbus
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Key switch position AUTO
Key switch position HAND
Braking resistance
PTC thermistor monitoring
2 Actuator outputs
Control unit
Internal DC link
Selector switch (Positions: REV - OFF - FWD)
Thermo-click with safe isolation
Breaking resistance
PC connection
IGBT inverter
1 potentiometer speed
Brake chopper with braking resistance for dynamic braking
STO (Safe Torque Off)
3 fixed speeds
4-quadrant operation possible
General
NEMA 12
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
AC voltage
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, Off-delay
U/f control
BLDC motors
PM and LSPM motors
Synchronous reluctance motors
At 40 °C
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
AC voltage
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Specification: S-7.4 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length