RASP5-5421EIP-412R010S1 198909 Y7-198909 EATON ELECTRIC RASP5-5421EIP-412R010S1
RASP5-5421EIP-412R010S1
198909
Y7-198909
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller RASP5-5421EIP-412R010S1 functions as an advanced frequency inverter built to regulate motor speeds and streamline energy usage in automated machinery setups. These units provide essential motor control capabilities for commercial and industrial applications requiring reliable performance. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 5.6 A
- Power consumption: 58 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 0
- Number of analogue inputs: 0
- Number of digital outputs: 2
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
UL 61800-5-1
UL approval
RoHS
CE
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
PC connection
Selector switch (Positions: REV - OFF - FWD)
Thermo-click with safe isolation
Key switch position OFF/RESET
Key switch position AUTO
Internal DC link
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
PTC thermistor monitoring
2 Actuator outputs
Key switch position HAND
IGBT inverter
Manual override switch
1 potentiometer speed
3 fixed speeds
For actuation of motors with mechanical brake
General
NEMA 12
C1: for conducted emissions only
AC voltage
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
Sensorless vector control (SLV)
BLDC motors
U/f control
Synchronous reluctance motors
For 60 s every 600 s
480 V AC, 3-phase
AC voltage
Center-point earthed star network (TN-S network)
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Specification: S-7.4 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length