View larger
RASP5-5420PNT-412R000S1 199012 Y7-199012 EATON ELECTRIC RASP5-5420PNT-412R000S1
RASP5-5420PNT-412R000S1
199012
Y7-199012
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for decentralized automation, the Eaton Moeller RASP5-5420PNT-412R000S1 frequency converter provides local motor control and network communication in industrial plants. Drive technology enables precise process optimization by regulating motor operational speeds on demand.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 61800-5-1
RoHS
CE
UL approval
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: drivesConnect
Thermo-click with safe isolation
Key switch position HAND
Selector switch (Positions: REV - OFF - FWD)
2 Actuator outputs
Internal DC link
IGBT inverter
Key switch position AUTO
PTC thermistor monitoring
Manual override switch
Control unit
PC connection
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
1 potentiometer speed
General
NEMA 12
C1: for conducted emissions only
Phase-earthed AC supply systems are not permitted.
AC voltage
Ambient conditions, mechanical
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, On-delay
U/f control
BLDC motors
Sensorless vector control (SLV)
PM and LSPM motors
At 40 °C
480 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
AC voltage
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Number of slave addresses: 31 (AS-Interface®)
Specification: S-7.4 (AS-Interface®)
Cable
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length