View larger
RASP5-5420EIP-412R110S1 198912 Y7-198912 EATON ELECTRIC RASP5-5420EIP-412R110S1
RASP5-5420EIP-412R110S1
198912
Y7-198912
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-5420EIP-412R110S1 is a frequency converter engineered to modulate motor velocities in manufacturing operations. Industrial drives ensure reliable power delivery and precise mechanical handling across automated production equipment.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 4
- With control element (EF001538): true
- Application in industrial area permitted (EF007294): true
More info
▲General specifications
IEC/EN 61800-5-1
CE
RoHS
UL approval
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Manual override switch
Key switch position AUTO
Key switch position HAND
Braking resistance
Key switch position OFF/RESET
PTC thermistor monitoring
2 Actuator outputs
PC connection
Thermo-click with safe isolation
Control unit
Internal DC link
Selector switch (Positions: REV - OFF - FWD)
Breaking resistance
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
1 potentiometer speed
4-quadrant operation possible
STO (Safe Torque Off)
Brake chopper with braking resistance for dynamic braking
General
NEMA 12
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Phase-earthed AC supply systems are not permitted.
AC voltage
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
In accordance with IEC/EN 50178
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, On-delay
BLDC motors
U/f control
PM and LSPM motors
Sensorless vector control (SLV)
For 60 s every 600 s
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
AC voltage
Motor rating
Braking function
Short-circuit rating
Control circuit
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mA
Number of slave addresses: 31 (AS-Interface®)
Cable
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length