View larger
RASP5-5404A31-512R100S1 198577 Y7-198577 EATON ELECTRIC RASP5-5404A31-512R100S1
RASP5-5404A31-512R100S1
198577
Y7-198577
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller RASP5-5404A31-512R100S1 is a frequency converter engineered to regulate motor speeds and optimize process efficiency within industrial setups. Variable frequency drives of this classification dynamically adjust power delivery to match mechanical load demands, minimizing energy consumption and mechanical wear on rotating equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
IEC/EN 61800-5-1
UL approval
RoHS
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Selector switch (Positions: REV - OFF - FWD)
PTC thermistor monitoring
Manual override switch
Internal DC link
Key switch position HAND
IGBT inverter
Control unit
Braking resistance
Key switch position OFF/RESET
Breaking resistance
Thermo-click with safe isolation
Key switch position AUTO
3 fixed speeds
1 potentiometer speed
4-quadrant operation possible
Brake chopper with braking resistance for dynamic braking
General
NEMA 12
AS-Interface profile cable: S-7.4 for 31 modules
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
AC voltage
Center-point earthed star network (TN-S network)
Ambient conditions, mechanical
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
Sensorless vector control (SLV)
U/f control
PM and LSPM motors
Synchronous reluctance motors
At 40 °C
400 V AC, 3-phase
AC voltage
Center-point earthed star network (TN-S network)
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
400/480 V AC (external brake 50/60 Hz)
Communication
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Number of slave addresses: 31 (AS-Interface®)
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length