View larger
RASP5-5402A31-412R000S1 198818 Y7-198818 EATON ELECTRIC RASP5-5402A31-412R000S1
RASP5-5402A31-412R000S1
198818
Y7-198818
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The RASP5-5402A31-412R000S1 Eaton Moeller frequency inverter regulates motor speeds in complex machinery and automated conveyor systems. Variable frequency drives allow operators to optimize mechanical processes, reduce energy consumption, and protect equipment from sudden mechanical shock during startup. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL approval
CE
UL 61800-5-1
RoHS
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
IGBT inverter
Key switch position AUTO
Selector switch (Positions: REV - OFF - FWD)
PTC thermistor monitoring
Control unit
Key switch position OFF/RESET
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
Internal DC link
PC connection
Key switch position HAND
3 fixed speeds
1 potentiometer speed
General
NEMA 12
AS-Interface profile cable: S-7.4 for 31 modules
C1: for conducted emissions only
AC voltage
Phase-earthed AC supply systems are not permitted.
Ambient conditions, mechanical
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm
Resistance: According to IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
< 95 %, no condensation
Main circuit
Adjustable, motor, main circuit
< 10 ms, Off-delay
Sensorless vector control (SLV)
PM and LSPM motors
U/f control
BLDC motors
For 60 s every 600 s
480 V AC, 3-phase
AC voltage
Phase-earthed AC supply systems are not permitted.
Motor rating
Braking function
Adjustable to 100 % (I/Ie), DC - Main circuit
Short-circuit rating
Control circuit
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
Communication
Specification: S-7.4 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C2 ≤ 5 m, maximum motor cable length
C3 ≤ 25 m, maximum motor cable length