View larger
RASP5-5402A31-4120000S1 198802 Y7-198802 EATON ELECTRIC RASP5-5402A31-4120000S1
RASP5-5402A31-4120000S1
198802
Y7-198802
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Rapid Link Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller RASP5-5402A31-4120000S1 variable frequency drive manages automated motor sequences within decentralized drive networks. These components are typically installed directly on machinery frames to control motor speeds and handle localized processing loads without centralized cabinet space.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.6 A
- Power consumption (EF000346): 58 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS
CE
IEC/EN 61800-5-1
UL approval
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Parameterization: Fieldbus
Parameterization: drivesConnect
Key switch position AUTO
Key switch position OFF/RESET
Selector switch (Positions: REV - OFF - FWD)
Key switch position HAND
Four fixed speeds
PC connection
PTC thermistor monitoring
Internal DC link
IGBT inverter
Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation
Thermo-click with safe isolation
General
NEMA 12
AS-Interface profile cable: S-7.4 for 31 modules
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Phase-earthed AC supply systems are not permitted.
AC voltage
Ambient conditions, mechanical
Resistance: According to IEC/EN 60068-2-6
Resistance: 10 - 150 Hz, Oscillation frequency
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Climatic environmental conditions
Max. 2000 m
In accordance with IEC/EN 50178
Main circuit
0.5 - 5.6 A, motor, main circuit
< 10 ms, On-delay
Sensorless vector control (SLV)
BLDC motors
PM and LSPM motors
Synchronous reluctance motors
At 40 °C
400 V AC, 3-phase
Phase-earthed AC supply systems are not permitted.
AC voltage
Motor rating
Braking function
≤ 30 % (I/Ie)
Short-circuit rating
Control circuit
230/277 V AC (external brake 50/60 Hz)
Communication
Number of slave addresses: 31 (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA
Cable
C3 ≤ 25 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length